June 2007 Replacing basic chassis components
1005r Server Maintenance and Diagnostics 111
Figure 18: Processor air duct
5 Lift the air duct from the server platform and store it in a safe
location.
To replace the processor air duct
1 Place the processor air duct over the processor socket and four-fan
assembly. Make sure you do not pinch any wires beneath the edges
of the air duct. Refer to “Processor air duct” on page 111.
2 Tighten the screws at the top of the air duct. The top of the installed
air duct must be flush with the top surface of the PCI adapter
assembly.
3 Replace the chassis cover. Refer to “Removing and replacing the
server cover” on page 108.
4 Take the ESD strap off.