Seitenansicht 569
570 Busy Tone Detection for Japan
Prompt Response Description
TYPE COT Central Office Trunk.
TN
lscu
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
XTRK XUT Enhanced Extended Universal Trunk.
...
SIGL LOP Loop start signaling.
...
SUPN YES Answer and disconnect supervision required.
If SUPN = YES, then the values stored in supervision type
(STYP prompt) are initialized and only the current entered
values are saved. Therefore, complete supervision is required
every time through this branch.
- STYP
xxx
Trunk supervision type where xxx is:
PIP = Polarity Insensitive
JCO = Japan Central Office
BTS = Busy Tone Supervision
...
BTDT (0)-7 Busy Tone Detection Table.
This table must be defined in LD 97.
LD 14 - Assign Busy Tone Detection to Direct Inward Dialing (DID) Trunks.
Prompt Response Description
REQ NEW
CHG
Add new data.
Change existing data.
TYPE DID Direct Inward Dialing Trunk.
TN
lscu
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
XTRK XUT Enhanced Extended Universal Trunk.
...
SIGL LOP Loop start signaling.
...
SUPN YES Supervision.
This response is automatically prompted YES for DID LOP.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106 01.04 Standard
Release 5.0 27 July 2007