Install filter and NTND26 cable (for MSDL and DCHIP cards in different Large System equipment
rows) 203
5
Use the NTMF04BA Extension Cable to connect the DCH (P5)
connector of the NTCW84KA to the inward side of the 15-pin I/O
panel filter connector.
—End—
Small System cable installation
Follow the steps in Procedure 13 "Installing cables on Small Systems" (page
203) for Small System cable installation.
Procedure 13
Installing cables on Small Systems
Step Action
1
Set the switches and jumper plugs in the NTAK02 SDI/DCH card as
shown. See Table 45 "NTAK02 SDI/DCH switch settings for IP Trunk
3.01 (and later) DCHIP" (page 203) and Table 46 "NTAK02 SDI/DCH
jumper settings for the IP Tr unk 3.01 (and later) DCHIP" (page 203).
Table 45
NTAK02 SDI/DCH switch settings for IP Trunk 3.01 (and later) DCHIP
Port 1
SW 1-1 SW 1-2
DCH OFF OFF
Port 3
SW 1-3 SW 1-4
DCH OFF OFF
Table 46
NTAK02 SDI/DCH jumper settings for the IP Trunk 3.01 (and later)
DCHIP
Port
Jumper
location
Strap for
DTE
Jumper
location RS422
J7 C B J9 C BPort 1
J6 C B J8 C B
J4 C B J2 C BPort 3
J3 C B J1 C B
2
Connect the NTAK19FB Quad Serial I/O SDI/DCH Cable (or
equivalent) to the I/O connector for the card slot in which the
SDI/DCH card is installed.
3
If the DCHIP card is installed in the main cabinet with the SDI/DCH
card, then use NTWE04AD SDI/DCH Extension Cable (1 ft) from the
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.