Install PRI hardware 213
LD 17 - Adding a D-channel interface
Prompt Response Description
REQ CHG Change existing data.
TYPE ADAN Action Device And Number.
- ADAN NEW DCH xx
CHG DCH xx
OUT DCH xx
Add a primary D-channel (any unused SDI port.)
Change a primary D-channel.
Remove the primary D-channel, where:
xx =0-79.
- CTYP DCHI
MSDL
TMDI
DCHI = D-channel configuration for the NTAK09 card or
NTAK93.
MSDL = NTBK51 Downloadable D-channel daughterboard.
TMDI = D-channel configuration on TMDI (NTRB21) card.
- CDNO
1-50
Card slot number to be used as the primary DDCH/DCHI.
Card slots 10, 20, 30, 40, and 50 are only applicable for
D-channel configuration of ISL or VNS.
- PORT
1
PORT must be set to 1.
- DES <CR> Designator.
- USR PRI D-channel is for ISDN PRI only.
- IFC
xx
Interface type.
- - DCHL
xx
PRI loop number.
- OTBF 1-(16)-127 Number of output request buffers.
Note: For a single PRI link, leave this prompt at default (16).
Add 5 output request buffers per additional link.
- DRAT 64KC D-channel transmission rate.
- SIDE NET (USR) Prompted only if IFC is set to SL1.
NET = network, the controlling switch.
USR = slave to the controller.
- RLS
xx
Release ID of the switch at the far-end of the D-channel.
- RCAP ND2 Remote capability.
- OVLR YES (NO) Allow or disallow overlap receiving on a D-channel. Default
is NO. Enter carriage return if settings are to be left at
default.