Chapter 7 Using the BCM Fault Management System 157
BCM50 Administration Guide
4 The Enable Alarm Set column indicates whether the alarm will display on the alarm set.
To test an alarm
1 Click the Administration tab.
2 Open the General folder, and then click the Alarm Settings task.
The Alarm Settings panel opens.
3 In the Alarms table, select an alarm.
4 Click the Test Alarm button.
In the Alarms table, “Test Event” is displayed in the alarm Problem Description field.
List of BCM alarms
Table 51 lists BCM alarms. The table includes the default handling of each alarm with respect to
the Alarms table, the alarm set, LEDs, and SNMP traps.
You can customize whether each alarm appears in the Alarms table or is sent as an SNMP trap in
accordance with your business requirements.
Table 51 List of alarms
#
Alarm
ID
Severity
Component
Name
Problem
Description
Problem
Resolution
Alarm SNMP LED
Alarm
Set
1 18 minor Core
Telephony
Core Telephony -
Unable to process
calls.
Reboot system and
contact your local
support group.
Yes No No No
2 31 critical Core
Telephony
Core Telephony -
Media Bay Module
firmware download
failed.
Power down the
system and check
the DTM hardware
and the expansion
chassis connections.
If problem persists
replace the DTM or
expansion chassis
hardware.
Yes Yes Yes Yes
3 32 critical Core
Telephony
Core Telephony -
BRI module is
primary clock
instead of DTM
module.
Configure the DTM
module as primary
clock in your system.
BRI clock
specifications are
not acceptable for
DTM connections to
the public network.
Yes Yes Yes Yes
4 33 critical Core
Telephony
Core Telephony -
Cold restart has
occurred causing
loss of telephony
data.
Check configuration
change logs to see if
this was user
initiated. If not
contact your local
support group.
Yes Yes Yes Yes
5 34 warning Core
Telephony
Core Telephony -
Media Bay Module
firmware download
started.
No Action Required. Yes No No No