Nortel Communication Server 1000
Nortel Communication Server 1000 Release 4.5
Circuit Card
Description and Installation
Document Number: 553-3001-211
Document Release: Standard 3.00
Date: August 2005
Year Publish FCC TM
Copyright © Nortel Networks Limited 2005
All Rights Reserved
Produced in Canada
Information is subject to change without notice. Nortel Networks reserves the right to make changes in design
or components as progress in engineering and manufacturing may warrant.
Nortel, Nortel (Logo), the Globemark, This is the Way, This is Nortel (Design mark), SL-1, Meridian 1, and
Succession are trademarks of Nortel Networks.
Title page
Seitenansicht 0
1 2 3 4 5 6 ... 907 908

Inhaltsverzeichnis

Seite 1 - Circuit Card

Nortel Communication Server 1000Nortel Communication Server 1000 Release 4.5Circuit CardDescription and InstallationDocument Number: 553-3001-211Docum

Seite 2

Page 10 of 906 Contents 553-3001-211 Standard 3.00 August 2005NT6D80 MSDL card . . . . . . . . . . . . . . . . . . . . . . . . 389Contents . . . .

Seite 3 - Revision history

Page 100 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005

Seite 4

Page 101 of 906Circuit Card Description and Installation156Option settingsContentsThis section contains information on the following topics:Circuit ca

Seite 5

Page 102 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC528 CO/FX/WATS Trunk cards . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 6 - Page 6 of 906 Contents

Option settings Page 103 of 906Circuit Card Description and InstallationThroughout this document, if neither ON nor OFF is given (there is a blank s

Seite 7

Page 104 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT1R20 Off-Premise Station cardTable 14 lists option settings for the NT1R20 Off

Seite 8

Option settings Page 105 of 906Circuit Card Description and InstallationLoop loss (dB) (Note 3)0–1.5 >1.5–2.5 >2.5–3.0 0–1.5 >1.5–2.5

Seite 9 - Contents Page 9 of 906

Page 106 of 906 Option settings553-3001-211 Standard 3.00 August 2005BIMP (Notes 1, 4)600 ohms3COM1 3COM2 600 ohms3COM1 3COM2 3COM2Gain treatment (No

Seite 10 - Page 10 of 906 Contents

Option settings Page 107 of 906Circuit Card Description and InstallationNT5D12AA Dual DTI/PRI (DDP) cardSwitch setting tables for this card are list

Seite 11 - NT8D09 Analog Message Waiting

Page 108 of 906 Option settings553-3001-211 Standard 3.00 August 2005A set of three switches provides selection of dB values. Use SW5, SW6, and SW7 f

Seite 12 - Page 12 of 906 Contents

Option settings Page 109 of 906Circuit Card Description and InstallationRing ground switchesA set of four DIP switches selects which Ring lines are

Seite 13 - Contents Page 13 of 906

Contents Page 11 of 906Circuit Card Description and InstallationUpgrading systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 14 - Page 14 of 906 Contents

Page 110 of 906 Option settings553-3001-211 Standard 3.00 August 2005DCH mode and address select switchesOne switch selects an on-board NTBK51AA D-Ch

Seite 15 - NTDK20 Small System

Option settings Page 111 of 906Circuit Card Description and InstallationIllustrations of switch locations and settingsFigure 18 on page 112 displays

Seite 16 - QPC513 Enhanced Serial Data

Page 112 of 906 Option settings553-3001-211 Standard 3.00 August 2005Figure 18Switch functions and areasJ5J6Port 0 Port 1 S3S2 S4S5S6S7S8S91 2 3

Seite 17 - Contents Page 17 of 906

Option settings Page 113 of 906Circuit Card Description and InstallationFigure 19 displays default settings for switches on the NT5D12AA DDP card.Fi

Seite 18 - Page 18 of 906 Contents

Page 114 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT6D42 Ringing Generator DCTables 22 through 27 list option settings for the NT6

Seite 19 - LIst of procedures

Option settings Page 115 of 906Circuit Card Description and InstallationTable 25NT6D42 SW1Ringing frequency (Hz) Position SW120 125 250 3Table 26NT6

Seite 20

Page 116 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 27NT6D42CC SW2SW2Ringing voltageMessage waitingvoltage1 2 3 486 V ac –100

Seite 21 - About this document

Option settings Page 117 of 906Circuit Card Description and InstallationNT5D2101/NT9D1102 Core/Network module backplaneNT6D68 Core module backplaneT

Seite 22 - Applicable systems

Page 118 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT6D80 Multi-purpose Serial Data Link cardTable 30NT6D80 Multi-purpose Serial Da

Seite 23 - Intended audience

Option settings Page 119 of 906Circuit Card Description and InstallationNT8D14 Universal Trunk cardTables 31 through 35 list option settings for the

Seite 24 - Conventions

Page 12 of 906 Contents 553-3001-211 Standard 3.00 August 2005Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 25 - Related information

Page 120 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 32NT8D14 vintages BA/BB jumper strap settings—factory standardTrunk typesL

Seite 26

Option settings Page 121 of 906Circuit Card Description and InstallationTable 33NT8D14 vintages BA/BB jumper strap settings—extended rangeTrunk type

Seite 27

Page 122 of 906 Option settings553-3001-211 Standard 3.00 August 20052-way tie (OAID) 600 or 900 ohms600 ohms 3COM1 3COM2DID (loop < 600 ohms) 60

Seite 28 - Line cards

Option settings Page 123 of 906Circuit Card Description and InstallationTable 35NT8D14 vintages BA/BB cable loop resistance and lossCable lengthCabl

Seite 29 - Overview Page 29 of 906

Page 124 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT8D15 E&M Trunk cardTable 36NT8D15 E&M Trunk cardJumper (Note 1)Mode of

Seite 30

Option settings Page 125 of 906Circuit Card Description and InstallationNT8D17 Conference/TDS cardSwitch and jumper settings are used to select the

Seite 31

Page 126 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT8D21 Ringing Generator ACFrequency AmplitudeSettingsP1 P2 P320 Hz 86 V ac ope

Seite 32

Option settings Page 127 of 906Circuit Card Description and InstallationNT8D22 System MonitorThe master system monitor, located in the column with C

Seite 33 - Overview Page 33 of 906

Page 128 of 906 Option settings553-3001-211 Standard 3.00 August 2005Configure the system monitor in Remote Peripheral Equipment (RPE) columns as sla

Seite 34 - Figure 2

Option settings Page 129 of 906Circuit Card Description and InstallationTable 38NT8D22 SW2SW2 indicationPosition1 2 3 4 5 6 7 8Master system monitor

Seite 35 - Overview Page 35 of 906

Contents Page 13 of 906Circuit Card Description and InstallationApplications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 36 - DS-30X loop data format

Page 130 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 40NT8D22 settings for total number of slaves—SW2 on masterHow many slave u

Seite 37 - Analog line interface units

Option settings Page 131 of 906Circuit Card Description and InstallationTable 41NT8D22 slave address—SW2 on slaveSlave unitaddressPositionSlave unit

Seite 38 - Figure 4

Page 132 of 906 Option settings553-3001-211 Standard 3.00 August 2005NT8D41BA Quad Serial Data Interface Paddle BoardBaud rateSwitches SW13, SW10, SW

Seite 39 - Overview Page 39 of 906

Option settings Page 133 of 906Circuit Card Description and Installationconfigurations for both switches are shown in Table 43. To avoid system prob

Seite 40 - Digital line interface units

Page 134 of 906 Option settings553-3001-211 Standard 3.00 August 2005 NT8D72 Primary Rate Interface cardThe NT8D72 Primary Rate Interface card allows

Seite 41 - Figure 5

Option settings Page 135 of 906Circuit Card Description and InstallationFigure 20NT8D72 DIP switch settingsS1 S21122or75 ohm switch setting 120 ohm

Seite 42 - Analog line call operation

Page 136 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC43 Peripheral Signaling cardQPC71 E&M/DX Signaling and Paging Trunk cards

Seite 43 - Figure 6

Option settings Page 137 of 906Circuit Card Description and InstallationQPC414 Network cardApplicationPin connection J3/S2 and J4/S1T-1 facilities (

Seite 44 - Figure 7

Page 138 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC441 3-Port Extender cardsFor CS 1000M SG and Multi Group systems, QPC441 vint

Seite 45 - Overview Page 45 of 906

Option settings Page 139 of 906Circuit Card Description and InstallationTable 46QPC441 3PE card installed in the NT5D21 modulesJumper Settings: Set

Seite 46 - Lineside T1 call operation

Page 14 of 906 Contents 553-3001-211 Standard 3.00 August 2005NTAK79 2.0 Mb PRI card . . . . . . . . . . . . . . . . . . . . 745Contents . . . . .

Seite 47 - Figure 8

Page 140 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 47QPC441 3PE card installed in the NT8D35 moduleJumper Settings: Set Jumpe

Seite 48 - 553-AAA1116

Option settings Page 141 of 906Circuit Card Description and Installation QPC559, QPC560 Loop Signaling Trunk cardsTable 48 and Table 49 on page 142

Seite 49 - Overview Page 49 of 906

Page 142 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 49QPC559, QPC560 double densityApplicationDouble density—Unit 0/1/2/3 H17/

Seite 50 - Page 50 of 906 Overview

Option settings Page 143 of 906Circuit Card Description and Installation QPC528 CO/FX/WATS Trunk cards Table 50 lists switch and jumper settings for

Seite 51

Page 144 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC471 Clock Controller cardTable 51 lists option settings for the QPC471 Clock

Seite 52

Option settings Page 145 of 906Circuit Card Description and InstallationQPC525, QPC526, QPC527, QPC777 CO Trunk cardNote 1: There is no ground start

Seite 53 - Overview Page 53 of 906

Page 146 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC550 Direct Inward Dial Trunk cardTables 52 through 56 give the option setting

Seite 54

Option settings Page 147 of 906Circuit Card Description and InstallationTable 54QPC550 vintage A—software/hardware control for 2dB padDevice locatio

Seite 55

Page 148 of 906 Option settings553-3001-211 Standard 3.00 August 2005Table 56QPC550 vintage B—software control for 2dB padDevice locationDevice desig

Seite 56 - Page 56 of 906 Overview

Option settings Page 149 of 906Circuit Card Description and InstallationQPC551 Radio Paging Trunk cardSignal duration on the 18-pair faceplate S1 (F

Seite 57 - Line protectors

Contents Page 15 of 906Circuit Card Description and InstallationFunctional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 58 - Line protection grounding

Page 150 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC595 Digitone Receiver cardsQPC577, QPC596 Digitone Receiver daughterboardsQPC

Seite 59 - Trunk cards

Option settings Page 151 of 906Circuit Card Description and Installation1, 3, 7 on 136–225 m(451–750 ft)101–200 m(356–655 ft)Switch 3 option for DTI

Seite 60

Page 152 of 906 Option settings553-3001-211 Standard 3.00 August 2005QPC775 Clock Controller cardTables 58 and 59 give option settings for the QPC775

Seite 61

Option settings Page 153 of 906Circuit Card Description and InstallationQPC841 4-Port Serial Data Interface cardTables 60 through 62 list option set

Seite 62 - Figure 10

Page 154 of 906 Option settings553-3001-211 Standard 3.00 August 2005Device number SW15Port 3 Port 4 1 2 3 4 5 6 7 80 1 off off off off off on on on2

Seite 63

Option settings Page 155 of 906Circuit Card Description and InstallationTable 62QPC841 DTE or DCE selectionMode Port 1—SW8 Port 1—SW91 2 3 4 5 6 1 2

Seite 64 - 553-6156

Page 156 of 906 Option settings553-3001-211 Standard 3.00 August 2005

Seite 65 - Overview Page 65 of 906

Page 157 of 906Circuit Card Description and Installation182NT1R20 Off-Premise Station Analog Line card ContentsThis section contains information on th

Seite 66 - Page 66 of 906 Overview

Page 158 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005used whenever the phone lines have to leave the buil

Seite 67 - Figure 12

NT1R20 Off-Premise Station Analog Line card Page 159 of 906Circuit Card Description and InstallationFigure 21OPS analog line card – faceplateSOPSAnl

Seite 68 - Figure 13

Page 16 of 906 Contents 553-3001-211 Standard 3.00 August 2005Software description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 69 - Trunk interface unit

Page 160 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Functional descriptionThis functional description of

Seite 70 - Figure 14

NT1R20 Off-Premise Station Analog Line card Page 161 of 906Circuit Card Description and InstallationCard interfacesVoice and signaling interfacesThe

Seite 71 - Overview Page 71 of 906

Page 162 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Line interface unitsThe NT1R20 OPS analog line card

Seite 72

NT1R20 Off-Premise Station Analog Line card Page 163 of 906Circuit Card Description and Installation— firmware version— self-test status— programmed

Seite 73

Page 164 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005See Software Input/Output: Administration (553-3001-

Seite 74

NT1R20 Off-Premise Station Analog Line card Page 165 of 906Circuit Card Description and InstallationPort-to-port loss configurationThe loss plan for

Seite 75

Page 166 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Analog line interfaceTable 64 lists the electrical c

Seite 76

NT1R20 Off-Premise Station Analog Line card Page 167 of 906Circuit Card Description and InstallationPower requirementsTable 65 shows the maximum pow

Seite 77 - Overview Page 77 of 906

Page 168 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Environmental specificationsTable 67 shows the envir

Seite 78 - Page 78 of 906 Overview

NT1R20 Off-Premise Station Analog Line card Page 169 of 906Circuit Card Description and InstallationIncoming callsIncoming calls to a telephone conn

Seite 79 - Circuit card installation

Contents Page 17 of 906Circuit Card Description and InstallationConfiguring the QSDI card . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 80

Page 170 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Outgoing callsFor outgoing calls from a telephone, a

Seite 81 - Component Large System

NT1R20 Off-Premise Station Analog Line card Page 171 of 906Circuit Card Description and InstallationOutpulsing Addressing signals Near-end station d

Seite 82

Page 172 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Connector pin assignmentsThe OPS analog line card br

Seite 83

NT1R20 Off-Premise Station Analog Line card Page 173 of 906Circuit Card Description and InstallationFigure 23OPS analog line card – typical cross co

Seite 84 - Precautions

Page 174 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Configuring the OPS analog line cardThe line type, t

Seite 85 - Static discharge points

NT1R20 Off-Premise Station Analog Line card Page 175 of 906Circuit Card Description and InstallationBefore the appropriate balance network can be se

Seite 86 - Installing a circuit card

Page 176 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Figure 24OPS analog line card – jumper block locatio

Seite 87 - 553-5002

NT1R20 Off-Premise Station Analog Line card Page 177 of 906Circuit Card Description and Installationlocal office, or through a distant office. The l

Seite 88

Page 178 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Figure 25Traditional OPS application configuration55

Seite 89 - Acceptance tests

NT1R20 Off-Premise Station Analog Line card Page 179 of 906Circuit Card Description and InstallationOther applicationsThe operating range and built-

Seite 90 - Conference cards

Page 18 of 906 Contents 553-3001-211 Standard 3.00 August 2005

Seite 91

Page 180 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005Port-to-port lossLoss is inserted between OPS analog

Seite 92 - Digitone receiver cards

NT1R20 Off-Premise Station Analog Line card Page 181 of 906Circuit Card Description and InstallationThe overall range achievable on an OPS line faci

Seite 93

Page 182 of 906 NT1R20 Off-Premise Station Analog Line card553-3001-211 Standard 3.00 August 2005OPS line terminations with loudness characteristics

Seite 94 - Multifrequency sender cards

Page 183 of 906Circuit Card Description and Installation192NT4N39AA CP Pentium IV CardContentsThis section contains information on the following topic

Seite 95 - Network cards

Page 184 of 906 NT4N39AA CP Pentium IV Card553-3001-211 Standard 3.00 August 2005The CP PIV front panel is equipped with an EMC gasket and two ejecto

Seite 96

NT4N39AA CP Pentium IV Card Page 185 of 906Circuit Card Description and InstallationFigure 26CP PIV card (front)Lan 1Lan 2COM 1COM 2

Seite 97 - Tone and digit switch cards

Page 186 of 906 NT4N39AA CP Pentium IV Card553-3001-211 Standard 3.00 August 2005Figure 27CP PIV card (side)Functional descriptionThe card employs an

Seite 98

NT4N39AA CP Pentium IV Card Page 187 of 906Circuit Card Description and Installationdouble pumped address bus (addresses running at 2*100 MHz = 200

Seite 99

Page 188 of 906 NT4N39AA CP Pentium IV Card553-3001-211 Standard 3.00 August 20054 DTR5 GND6 DSR7 RTS8 CTS9 RITable 72COM1 and COM2 pin assignments

Seite 100

NT4N39AA CP Pentium IV Card Page 189 of 906Circuit Card Description and InstallationUSB portThe physical interface for the USB port to the front pan

Seite 101 - Option settings

Page 19 of 906Circuit Card Description and Installation20LIst of proceduresProcedure 1Installation . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 102 - Circuit card grid

Page 190 of 906 NT4N39AA CP Pentium IV Card553-3001-211 Standard 3.00 August 2005Front panel LED indicators The CP PIV card has a total of five LEDS

Seite 103 - 553-5491

NT4N39AA CP Pentium IV Card Page 191 of 906Circuit Card Description and InstallationITP connector (25 PIN, Debug Only)Post 80 Debug LEDs (Optional)C

Seite 104 - BIMP: 600 ohms 3COM2

Page 192 of 906 NT4N39AA CP Pentium IV Card553-3001-211 Standard 3.00 August 2005

Seite 105

Page 193 of 906Circuit Card Description and Installation248NT5D11 and NT5D14 Lineside T1Interface cardsContentsThis section contains information on th

Seite 106

Page 194 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005mail systems, channel banks containing FXS cards,

Seite 107 - General purpose switches

NT5D11 and NT5D14 Lineside T1 Interface cards Page 195 of 906Circuit Card Description and InstallationFigure 29Lineside T1 card faceplateYEL ALMRED

Seite 108

Page 196 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005In general, the LEDs operate as shown in Table 76.

Seite 109 - Ring ground switches

NT5D11 and NT5D14 Lineside T1 Interface cards Page 197 of 906Circuit Card Description and InstallationNote: Note: The STATUS LED indicates the enabl

Seite 110

Page 198 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005“Man-Machine T1 maintenance interface software” on

Seite 111 - NT5D12AA DDP card

NT5D11 and NT5D14 Lineside T1 Interface cards Page 199 of 906Circuit Card Description and InstallationThe lineside T1 card is an IPE line card that

Seite 113 - 1 2 3 4

Page 20 of 906 LIst of procedures553-3001-211 Standard 3.00 August 2005Procedure 11Connecting to the MDF . . . . . . . . . . . . . . . . . . . . . .

Seite 114 - NT6D42 Ringing Generator DC

Page 200 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Card interfacesThe lineside T1 card passes voice a

Seite 115

NT5D11 and NT5D14 Lineside T1 Interface cards Page 201 of 906Circuit Card Description and InstallationMicrocontrollersThe lineside T1 card contains

Seite 116

Page 202 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Man-Machine InterfaceThe lineside T1 card provides

Seite 117 - NT6D68 Core module backplane

NT5D11 and NT5D14 Lineside T1 Interface cards Page 203 of 906Circuit Card Description and InstallationPower requirementsThe lineside T1 card require

Seite 118

Page 204 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Environmental specificationsTable 79 lists the env

Seite 119 - NT8D14 Universal Trunk card

NT5D11 and NT5D14 Lineside T1 Interface cards Page 205 of 906Circuit Card Description and InstallationDip switch settingsBegin the installation and

Seite 120 - Jumper pin

Page 206 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005LD 97 for type: XPE. However, this is not mandator

Seite 121

NT5D11 and NT5D14 Lineside T1 Interface cards Page 207 of 906Circuit Card Description and InstallationT1 framingThe lineside T1 card is capable of i

Seite 122

Page 208 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005cabled directly into the MMI terminal or modem; se

Seite 123

NT5D11 and NT5D14 Lineside T1 Interface cards Page 209 of 906Circuit Card Description and Installation05 Off On Off On06 Off On On Off07 Off On On O

Seite 124 - NT8D15 E&M Trunk card

Page 21 of 906Circuit Card Description and Installation26About this documentThis document is a global document. Contact your system supplier or your N

Seite 125 - NT8D17 Conference/TDS card

Page 210 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005InstallationThis section describes how to install

Seite 126 - NT8D21 Ringing Generator AC

NT5D11 and NT5D14 Lineside T1 Interface cards Page 211 of 906Circuit Card Description and InstallationCertain vintage levels have dedicated 25-pair

Seite 127 - NT8D22 System Monitor

Page 212 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Vintage levels cabling 16 portsFor modules with vi

Seite 128

NT5D11 and NT5D14 Lineside T1 Interface cards Page 213 of 906Circuit Card Description and InstallationCabling the lineside T1 cardAfter configuring

Seite 129

Page 214 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 32Lineside T1 card – connection using the N

Seite 130

NT5D11 and NT5D14 Lineside T1 Interface cards Page 215 of 906Circuit Card Description and InstallationProcedure 11Connecting to the MDFTo make the c

Seite 131

Page 216 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 200513A 2 T1 Tip, Transmit Data13B 27 T1 Ring, Transmi

Seite 132 - For future use

NT5D11 and NT5D14 Lineside T1 Interface cards Page 217 of 906Circuit Card Description and InstallationTable 86 shows the pin assignments when using

Seite 133

Page 218 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005T1 connectionsT1 signaling for all 24 channels is

Seite 134

NT5D11 and NT5D14 Lineside T1 Interface cards Page 219 of 906Circuit Card Description and InstallationOne of the ways it can report information is t

Seite 135 - NT8D72 DIP switch settings

Page 22 of 906 About this document553-3001-211 Standard 3.00 August 2005information about system messages, see the Software Input/Output: System Mess

Seite 136

Page 220 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Procedure 12Connecting two or more lineside T1 car

Seite 137 - QPC414 Network card

NT5D11 and NT5D14 Lineside T1 Interface cards Page 221 of 906Circuit Card Description and InstallationFigure 33Lineside T1 card – connecting two or

Seite 138 - QPC441 3-Port Extender cards

Page 222 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Terminal configurationFor the MMI terminal to be a

Seite 139

NT5D11 and NT5D14 Lineside T1 Interface cards Page 223 of 906Circuit Card Description and Installationcross-referenced to the corresponding card uni

Seite 140

Page 224 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Disconnect supervisionThe lineside T1 card support

Seite 141

NT5D11 and NT5D14 Lineside T1 Interface cards Page 225 of 906Circuit Card Description and InstallationMan-Machine T1 maintenance interface softwareD

Seite 142

Page 226 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Two levels of alarm severity exist for bit errors

Seite 143

NT5D11 and NT5D14 Lineside T1 Interface cards Page 227 of 906Circuit Card Description and Installation• bursty seconds • unavailable seconds • frame

Seite 144 - QPC471 Clock Controller card

Page 228 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005A space is inserted between the login command (L),

Seite 145

NT5D11 and NT5D14 Lineside T1 Interface cards Page 229 of 906Circuit Card Description and InstallationIf ?<CR> is typed, the MMI will list the

Seite 146

About this document Page 23 of 906Circuit Card Description and InstallationSystem migration When particular Meridian 1 systems are upgraded to run C

Seite 147

Page 230 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005C E Clear ErrorClears the error counter for the T1

Seite 148

NT5D11 and NT5D14 Lineside T1 Interface cards Page 231 of 906Circuit Card Description and InstallationQ Quit Logs the terminal user out. If multiple

Seite 149

Page 232 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Configuring parametersThe MMI has been designed wi

Seite 150

NT5D11 and NT5D14 Lineside T1 Interface cards Page 233 of 906Circuit Card Description and InstallationWhen the Set Alarm command is used, a prompt a

Seite 151

Page 234 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Clearing” option has been set. Otherwise, the alar

Seite 152 - QPC775 Clock Controller card

NT5D11 and NT5D14 Lineside T1 Interface cards Page 235 of 906Circuit Card Description and InstallationWhen entering the Set Alarm command set, the M

Seite 153

Page 236 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005The “Disable Self-Clearing” option causes the syst

Seite 154

NT5D11 and NT5D14 Lineside T1 Interface cards Page 237 of 906Circuit Card Description and InstallationDescriptions of the excessive bit error rate a

Seite 155

Page 238 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005mode, yellow alarms can be sent and the lineside T

Seite 156

NT5D11 and NT5D14 Lineside T1 Interface cards Page 239 of 906Circuit Card Description and Installationof the lineside T1 card. Entering the Display

Seite 157 - Analog Line card

Page 24 of 906 About this document553-3001-211 Standard 3.00 August 2005Conventions TerminologyIn this document, the following systems are referred t

Seite 158 - Physical description

Page 240 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005• Loss of frame seconds – loss of frame or loss of

Seite 159 - 553-6190

NT5D11 and NT5D14 Lineside T1 Interface cards Page 241 of 906Circuit Card Description and InstallationDisplay HistoryEnter the Display History (D H)

Seite 160 - Functional description

Page 242 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Tests can be performed once (for 1 through 98 minu

Seite 161 - Card interfaces

NT5D11 and NT5D14 Lineside T1 Interface cards Page 243 of 906Circuit Card Description and InstallationTest 2, external loopback, assumes an external

Seite 162 - Card control functions

Page 244 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005in tandem. Figure 36 demonstrates how the signalin

Seite 163

NT5D11 and NT5D14 Lineside T1 Interface cards Page 245 of 906Circuit Card Description and InstallationFor example, the lineside T1 card can be used

Seite 164

Page 246 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 38Lineside T1 interface in off-premise appl

Seite 165 - Electrical specifications

NT5D11 and NT5D14 Lineside T1 Interface cards Page 247 of 906Circuit Card Description and InstallationSimilarly, the lineside T1 can be used to prov

Seite 166 - Analog line interface

Page 248 of 906 NT5D11 and NT5D14 Lineside T1 Interface cards553-3001-211 Standard 3.00 August 2005

Seite 167 - Ringer limitations

Page 249 of 906Circuit Card Description and Installation312NT5D33 and NT5D34 Lineside E1Interface cardsContentsThis section contains information on th

Seite 168 - Operation

About this document Page 25 of 906Circuit Card Description and InstallationRelated informationThis section lists information sources that relate to

Seite 169 - Incoming calls

Page 250 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005in the Analog (500/2500-type) Telephone Administra

Seite 170 - Outgoing calls

NT5D33 and NT5D34 Lineside E1 Interface cards Page 251 of 906Circuit Card Description and Installationmotherboard (31.75 by 25.40 cm (12.5 by 10 in)

Seite 171

Page 252 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 40NT5D33AB LEI card – faceplate

Seite 172 - Connector pin assignments

NT5D33 and NT5D34 Lineside E1 Interface cards Page 253 of 906Circuit Card Description and InstallationFigure 41NT5D34AB LEI card – faceplate

Seite 173 - 553-AAA1117

Page 254 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005The LEDs give status indications on the operations

Seite 174 - Jumper strap settings

NT5D33 and NT5D34 Lineside E1 Interface cards Page 255 of 906Circuit Card Description and Installationcondition. Depending on how the Man Machine In

Seite 175 - Application

Page 256 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 42LEI card – block diagram

Seite 176 - 553-6191

NT5D33 and NT5D34 Lineside E1 Interface cards Page 257 of 906Circuit Card Description and InstallationOverviewThe LEI card is an IPE line card that

Seite 177

Page 258 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005E1 interface circuitThe LEI contains one E1 line-i

Seite 178 - 553-AAA1118

NT5D33 and NT5D34 Lineside E1 Interface cards Page 259 of 906Circuit Card Description and Installation— card identification (card type, vintage, ser

Seite 179 - Transmission considerations

Page 26 of 906 About this document553-3001-211 Standard 3.00 August 2005CD-ROMTo obtain Nortel documentation on CD-ROM, contact your Nortel customer

Seite 180

Page 260 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005provides alarm notification, E1 link performance r

Seite 181

NT5D33 and NT5D34 Lineside E1 Interface cards Page 261 of 906Circuit Card Description and Installation2 Redirecting Line ID Presentation (RLIP)When

Seite 182

Page 262 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Power requirementsTable 94 shows the voltage and m

Seite 183 - NT4N39AA CP Pentium IV Card

NT5D33 and NT5D34 Lineside E1 Interface cards Page 263 of 906Circuit Card Description and InstallationInstallation and ConfigurationInstallation and

Seite 184

Page 264 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005of the motherboard circuit card as shown in Figure

Seite 185

NT5D33 and NT5D34 Lineside E1 Interface cards Page 265 of 906Circuit Card Description and InstallationE1 CodingThe LEI is capable of interfacing wit

Seite 186

Page 266 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 44LEI card – E1 protocol dip switch locatio

Seite 187 - COM1 and COM2 ports

NT5D33 and NT5D34 Lineside E1 Interface cards Page 267 of 906Circuit Card Description and InstallationLine supervision on E1 failureThis setting det

Seite 188

Page 268 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005When dip switch #1, positions 2 and 8 are set to “

Seite 189 - USB port

NT5D33 and NT5D34 Lineside E1 Interface cards Page 269 of 906Circuit Card Description and InstallationTable 98LEI card – XPEC address dip switch set

Seite 190 - Front panel LED indicators

Page 27 of 906Circuit Card Description and Installation78OverviewContentsThis section contains information on the following topics:Line cards . . . .

Seite 191 - Post 80 Debug LEDs (Optional)

Page 270 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005When setting E1 Switch 2 dip switch settings, ther

Seite 192

NT5D33 and NT5D34 Lineside E1 Interface cards Page 271 of 906Circuit Card Description and InstallationAfter the card has been installed, display the

Seite 193 - Interface cards

Page 272 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005of module or cabinet. In all other modules or cabi

Seite 194

NT5D33 and NT5D34 Lineside E1 Interface cards Page 273 of 906Circuit Card Description and InstallationVintage levels cabling 30 ports: For modules w

Seite 195 - 553-6478

Page 274 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Alternatively, all LEI connections can be made at

Seite 196

NT5D33 and NT5D34 Lineside E1 Interface cards Page 275 of 906Circuit Card Description and InstallationThis cable consists of a 25-pair amphenol conn

Seite 197

Page 276 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Table 103 shows the pin assignments from the I/O p

Seite 198 - 553-6476

NT5D33 and NT5D34 Lineside E1 Interface cards Page 277 of 906Circuit Card Description and InstallationE1 Connections For twisted-pair installations,

Seite 199

Page 278 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005CPE at the far-end will likewise have transmit and

Seite 200 - Signaling and control

NT5D33 and NT5D34 Lineside E1 Interface cards Page 279 of 906Circuit Card Description and Installation128 LEIs can be linked, located in up to 16 se

Seite 201

Page 28 of 906 Overview553-3001-211 Standard 3.00 August 2005Line cardsThe following line cards are designed using the Intelligent Peripheral Equipme

Seite 202

Page 280 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 45LEI card – connecting two or more cards t

Seite 203

NT5D33 and NT5D34 Lineside E1 Interface cards Page 281 of 906Circuit Card Description and Installation• stop bits – one• software handshake (XON/XOF

Seite 204 - Environmental specifications

Page 282 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Motherboard 7 8Motherboard 8 9Motherboard 9 10Moth

Seite 205 - Dip switch settings

NT5D33 and NT5D34 Lineside E1 Interface cards Page 283 of 906Circuit Card Description and InstallationDisconnect supervisionThe LEI supports far-end

Seite 206 - Figure 31

Page 284 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Man-Machine E1 maintenance interface softwareDescr

Seite 207

NT5D33 and NT5D34 Lineside E1 Interface cards Page 285 of 906Circuit Card Description and InstallationTwo levels of alarm severity exist for bit err

Seite 208

Page 286 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005• framer-slip seconds• loss-of-frame seconds The M

Seite 209

NT5D33 and NT5D34 Lineside E1 Interface cards Page 287 of 906Circuit Card Description and InstallationLEI::ss cc> (for multi-card installations,

Seite 210 - Installation

Page 288 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Each of these commands can be executed by entering

Seite 211

NT5D33 and NT5D34 Lineside E1 Interface cards Page 289 of 906Circuit Card Description and InstallationD S(P) Display Status. Displays carrier status

Seite 212

Overview Page 29 of 906Circuit Card Description and InstallationNT1R20 Off-Premise Station Analog Line cardThe NT1R20 Off-Premise Station (OPS) Anal

Seite 213 - Cabling the lineside T1 card

Page 290 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Configuring parametersThe MMI has been designed wi

Seite 214 - Figure 32

NT5D33 and NT5D34 Lineside E1 Interface cards Page 291 of 906Circuit Card Description and Installation— an alarm message is created in the alarm log

Seite 215

Page 292 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005The duration value is set in seconds and can be se

Seite 216

NT5D33 and NT5D34 Lineside E1 Interface cards Page 293 of 906Circuit Card Description and InstallationAn alarm condition is not automatically cleare

Seite 217 - I/O cable

Page 294 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Note: If the duration period set is too long, the

Seite 218

NT5D33 and NT5D34 Lineside E1 Interface cards Page 295 of 906Circuit Card Description and InstallationWhen the far-end terminates a call, Release 1

Seite 219

Page 296 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005However, responding to this prompt with 2 selects

Seite 220

NT5D33 and NT5D34 Lineside E1 Interface cards Page 297 of 906Circuit Card Description and InstallationIdle SEND – This is the value that the LEI sen

Seite 221 - 553-6481

Page 298 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005unable to accept new calls. Set this value to N if

Seite 222 - Software configuration

NT5D33 and NT5D34 Lineside E1 Interface cards Page 299 of 906Circuit Card Description and InstallationIncoming call Ringer ON SEND – This is the val

Seite 223

Page 3 of 906Circuit Card Description and Installation4Revision historyAugust 2005Standard 3.00. This document is up-issued to support Communication S

Seite 224

Page 30 of 906 Overview553-3001-211 Standard 3.00 August 2005NT8D09 analog message waiting line cardThe NT8D09 Analog Message Waiting Line card is an

Seite 225 - Description

Page 300 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Outgoing call DIAL BREAK RECEIVE – This is the val

Seite 226

NT5D33 and NT5D34 Lineside E1 Interface cards Page 301 of 906Circuit Card Description and InstallationFigure 52Display Configuration (D C) screenAla

Seite 227 - Login and password

Page 302 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005seconds, neither a loss of signal, out-of-frame co

Seite 228 - Basic commands

NT5D33 and NT5D34 Lineside E1 Interface cards Page 303 of 906Circuit Card Description and InstallationFigure 53Display Alarm (D A) screenThe Pause c

Seite 229

Page 304 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 54Display Status (D S) screenPerformance co

Seite 230

NT5D33 and NT5D34 Lineside E1 Interface cards Page 305 of 906Circuit Card Description and Installation• Loss-of-frame seconds are seconds in which l

Seite 231 - Set Clearing

Page 306 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005The Pause command can be used to display a full sc

Seite 232 - Configuring parameters

NT5D33 and NT5D34 Lineside E1 Interface cards Page 307 of 906Circuit Card Description and InstallationTestingThe Test Carrier (T) command allows tes

Seite 233

Page 308 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Table 108 shows which test to run for the associat

Seite 234

NT5D33 and NT5D34 Lineside E1 Interface cards Page 309 of 906Circuit Card Description and InstallationFigure 60MMI External loopback testTest 3, net

Seite 235

Overview Page 31 of 906Circuit Card Description and InstallationWhen installing line cards, follow these general procedures:• Configure the jumpers

Seite 236 - Alarm operation and reporting

Page 310 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005ApplicationsThe LEI is an IPE line card that provi

Seite 237

NT5D33 and NT5D34 Lineside E1 Interface cards Page 311 of 906Circuit Card Description and Installationsend a call to the VRU, and, because the LEI s

Seite 238

Page 312 of 906 NT5D33 and NT5D34 Lineside E1 Interface cards553-3001-211 Standard 3.00 August 2005Figure 64LEI connection to Norstar systemE1Norstar

Seite 239

Page 313 of 906Circuit Card Description and Installation318NT5D60/80 CLASS Modem card (XCMC)ContentsThis section contains information on the following

Seite 240

Page 314 of 906 NT5D60/80 CLASS Modem card (XCMC)553-3001-211 Standard 3.00 August 2005The CLASS modem card circuitry is mounted on a 31.75 cm by 25.

Seite 241

NT5D60/80 CLASS Modem card (XCMC) Page 315 of 906Circuit Card Description and InstallationBell 202 standard. The transmission is implemented by the

Seite 242

Page 316 of 906 NT5D60/80 CLASS Modem card (XCMC)553-3001-211 Standard 3.00 August 20051213141512131415040506071617181916171819module 2, 000102032021

Seite 243 - 553-AAA1121

NT5D60/80 CLASS Modem card (XCMC) Page 317 of 906Circuit Card Description and InstallationElectrical specificationsThis section lists the electrical

Seite 244 - Applications

Page 318 of 906 NT5D60/80 CLASS Modem card (XCMC)553-3001-211 Standard 3.00 August 2005ConfigurationThe NT5D60/80 CLASS Modem card has no user-config

Seite 245 - Figure 37

Page 319 of 906Circuit Card Description and Installation366NT5D97 Dual-port DTI2/PRI2 cardContentsThe following are the topics in this section:Introdu

Seite 246 - Figure 38

Page 32 of 906 Overview553-3001-211 Standard 3.00 August 2005• configure the card according to instructions issued by the system • report back to the

Seite 247 - Figure 39

Page 320 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005The NT5D97 DDP2 card hardware design uses a B57 ASIC E1/T1 frame

Seite 248

NT5D97 Dual-port DTI2/PRI2 card Page 321 of 906Circuit Card Description and InstallationTable 112 indicates how the RR control signal operates with

Seite 249 - NT5D33 and NT5D34 Lineside E1

Page 322 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Figure 65NT5D97 faceplateD-Channel LEDENET LEDTrunk Disable LEDT

Seite 250

NT5D97 Dual-port DTI2/PRI2 card Page 323 of 906Circuit Card Description and InstallationTable 113External connectors and LEDsFunctionFaceplate Desig

Seite 251 - Faceplate

Page 324 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005The following sections provide a brief description of each eleme

Seite 252 - NT5D33AB LEI card – faceplate

NT5D97 Dual-port DTI2/PRI2 card Page 325 of 906Circuit Card Description and InstallationLBK LEDsTwo yellow LEDs indicate if a remote loopback test i

Seite 253 - NT5D34AB LEI card – faceplate

Page 326 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Port definitionsSince the NT5D97 card is dual-card, it equips tw

Seite 254

NT5D97 Dual-port DTI2/PRI2 card Page 327 of 906Circuit Card Description and InstallationSystem capacity and performancePhysical capacityEach NT5D97

Seite 255

Page 328 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Power requirementsTable 116 lists the power requirements for the

Seite 256 - LEI card – block diagram

NT5D97 Dual-port DTI2/PRI2 card Page 329 of 906Circuit Card Description and Installation— NTCG03AB— NTCG03AC— NTCG03AD• DDP2 to DCH cables— NTCK46AA

Seite 257 - Overview

Overview Page 33 of 906Circuit Card Description and Installation• ringing signal on/off• message waiting lamp on/offMaintenance data is data relatin

Seite 258 - E1 interface circuit

Page 330 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Table 117 which follows lists the pin attributes for the NTCK45A

Seite 259

NT5D97 Dual-port DTI2/PRI2 card Page 331 of 906Circuit Card Description and InstallationNT8D7217 (A0617192)The NT8D7217 (50 ft.) is an 120Ω cable fo

Seite 260 - ELEI additional functionality

Page 332 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005NTCK78AA (A0618294)The NTCK78AA (50 ft.) is an 120Ω cable for co

Seite 261

NT5D97 Dual-port DTI2/PRI2 card Page 333 of 906Circuit Card Description and InstallationTable 119 lists the pin attributes for the NTCK78AA cable.NT

Seite 262

Page 334 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Table 120 lists the pin attributes for the NTCK79AA cable. Figur

Seite 263

NT5D97 Dual-port DTI2/PRI2 card Page 335 of 906Circuit Card Description and InstallationReference clock cablesThe NTCG03AA (14 ft), NTCG03AB (2.8 ft

Seite 264

Page 336 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005• NTCK46AC (35 ft.) - DDP2 to DCH cable• NTCK46AD (50 ft.) - DDP

Seite 265 - E1 Coding

NT5D97 Dual-port DTI2/PRI2 card Page 337 of 906Circuit Card Description and InstallationCable diagramsFigure 73 on page 338 and Figure 74 on page 33

Seite 266 - Figure 44

Page 338 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Figure 73DDP2 cable for systems with an I/O panelLED'sSwitc

Seite 267

NT5D97 Dual-port DTI2/PRI2 card Page 339 of 906Circuit Card Description and InstallationFigure 74DDP2 cable for systems without an I/O panelLED&apos

Seite 268

Page 34 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 2Typical IPE analog line card architectureInput/outputinterfacecontrolCodecPCMMic

Seite 269

Page 340 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Functional descriptionNT5D97 circuit card locationsEach NT5D97 c

Seite 270

NT5D97 Dual-port DTI2/PRI2 card Page 341 of 906Circuit Card Description and InstallationThe following parameters are set by DIP switches. The boldfa

Seite 271

Page 342 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Figure 75Dip switches for NT5D97AA/AB

Seite 272

NT5D97 Dual-port DTI2/PRI2 card Page 343 of 906Circuit Card Description and InstallationTrunk interface switches for NT5D97AA/ABImpedance level and

Seite 273

Page 344 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Note: Do not change this setup.Receiver impedanceA per-trunk set

Seite 274 - Cabling the LEI card

NT5D97 Dual-port DTI2/PRI2 card Page 345 of 906Circuit Card Description and InstallationDCH Address select switch for NTBK51AA daughter board for NT

Seite 275

Page 346 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 20052 OFF ON OFF OFF3 ON ON OFF OFF4 OFF OFF ON OFF5 ON OFF ON OFF6

Seite 276

NT5D97 Dual-port DTI2/PRI2 card Page 347 of 906Circuit Card Description and InstallationNT5D97AD DIP switch settingsThe the NT5D97 DDP2 card is equi

Seite 277

Page 348 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Figure 76Dip switches locations for NT5D97AD1234S21234S101234S31

Seite 278

NT5D97 Dual-port DTI2/PRI2 card Page 349 of 906Circuit Card Description and InstallationTrunk interface switches for NT5D97ADTrunk 0 switchesSwitch

Seite 279

Overview Page 35 of 906Circuit Card Description and InstallationDS-30X loopsThe line interfaces provided by the line cards connect to conventional 2

Seite 280

Page 350 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Switch S6 selects the Receiver interface.Trunk 1 switches for NT

Seite 281 - Software Configuration

NT5D97 Dual-port DTI2/PRI2 card Page 351 of 906Circuit Card Description and InstallationDCH Address select switch for NTBK51AA daughterboard for NT5

Seite 282

Page 352 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005MSDL external cardUse Table 138 to set the card address. Table 1

Seite 283

NT5D97 Dual-port DTI2/PRI2 card Page 353 of 906Circuit Card Description and InstallationArchitectureClock operationThere are two types of clock oper

Seite 284

Page 354 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Reference clock errorsCS 1000 Release 4.5 software checks at int

Seite 285

NT5D97 Dual-port DTI2/PRI2 card Page 355 of 906Circuit Card Description and Installationsystem switches to the back-up clock controller, without aff

Seite 286 - Login and Password

Page 356 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Automatic clock switchingIf the EREF command is selected in LD 6

Seite 287 - HELP (H, ?) screen

NT5D97 Dual-port DTI2/PRI2 card Page 357 of 906Circuit Card Description and InstallationTable 139 summarizes the clocking options. Table 140 on page

Seite 288

Page 358 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Table 140Clock Controller options - descriptionClock OptionNotes

Seite 289

NT5D97 Dual-port DTI2/PRI2 card Page 359 of 906Circuit Card Description and InstallationOperationThe following discussion describes possible scenari

Seite 290

Page 36 of 906 Overview553-3001-211 Standard 3.00 August 2005DS-30Y network loops extend between controller cards and superloop network cards in the

Seite 291

Page 360 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Figure 79Clock Controller – Option 2553-7403PrimaryReferencePort

Seite 292

NT5D97 Dual-port DTI2/PRI2 card Page 361 of 906Circuit Card Description and InstallationFigure 80Clock Controller – Option 3553-7404PrimaryReference

Seite 293

Page 362 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005Case 1 - The two ports of a QPC414 network card are connected to

Seite 294

NT5D97 Dual-port DTI2/PRI2 card Page 363 of 906Circuit Card Description and InstallationCase 3 - The network shelf is full, one port of a QPC414 net

Seite 295

Page 364 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 20058 Run and connect the NT5D97 cables.9 If required, install conne

Seite 296 - Figure 49

NT5D97 Dual-port DTI2/PRI2 card Page 365 of 906Circuit Card Description and Installation3 If the NT5D97 card is being completely removed, not replac

Seite 297 - Set Mode (S M): Table screen

Page 366 of 906 NT5D97 Dual-port DTI2/PRI2 card553-3001-211 Standard 3.00 August 2005• Port 0 of the NTBK51AA can only be defined to work with Loop 0

Seite 298 - Table 99 on page 270

Page 367 of 906Circuit Card Description and Installation368NT5K02 Flexible Analog Line cardContentsThis section contains information on the following

Seite 299

Page 368 of 906 NT5K02 Flexible Analog Line card553-3001-211 Standard 3.00 August 2005ApplicationsThe NT5K02 Flexible Analog Line card can be used fo

Seite 300

Page 369 of 906Circuit Card Description and Installation378NT5K21 XMFC/MFE cardContentsThis section contains information on the following topics:Intro

Seite 301 - Figure 52

Overview Page 37 of 906Circuit Card Description and InstallationA card LAN link bus is common to all of the line/trunk card slots within an IPE modu

Seite 302

Page 370 of 906 NT5K21 XMFC/MFE card553-3001-211 Standard 3.00 August 2005Signaling levelsMFC signaling uses pairs of frequencies to represent digits

Seite 303 - Display Alarm (D A) screen

NT5K21 XMFC/MFE card Page 371 of 906Circuit Card Description and InstallationMFC signaling involves two or more levels of forward signals and two or

Seite 304 - Display Status (D S) screen

Page 372 of 906 NT5K21 XMFC/MFE card553-3001-211 Standard 3.00 August 2005The exact meaning of each MFC signal number (1-15) within each level can be

Seite 305 - Figure 55

NT5K21 XMFC/MFE card Page 373 of 906Circuit Card Description and InstallationSender and receiver modeThe XMFC/MFE circuit card provides the interfac

Seite 306 - Display History (D H) screen

Page 374 of 906 NT5K21 XMFC/MFE card553-3001-211 Standard 3.00 August 2005XMFC sender and receiver specificationsTable 143 and Table 144 provide the

Seite 307 - (1,2,3 or S to cancel):

NT5K21 XMFC/MFE card Page 375 of 906Circuit Card Description and InstallationXMFE sender and receiver specificationsTables 145 and Table 146 on pag

Seite 308 - 553-1160

Page 376 of 906 NT5K21 XMFC/MFE card553-3001-211 Standard 3.00 August 2005Physical specificationsTable 147 outlines the physical specifications of th

Seite 309 - 553-1162

NT5K21 XMFC/MFE card Page 377 of 906Circuit Card Description and InstallationCabinet Location Must be placed in the main cabinet (Slots 1-10)Power r

Seite 310

Page 378 of 906 NT5K21 XMFC/MFE card553-3001-211 Standard 3.00 August 2005

Seite 311 - Figure 63

Page 379 of 906Circuit Card Description and Installation384NT6D70 SILC Line cardContentsThis section contains information on the following topics:Intr

Seite 312 - Figure 64

Page 38 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 4Typical analog line interface unit block diagram CODEC2-wireto4-wireconversionLi

Seite 313 - Introduction

Page 380 of 906 NT6D70 SILC Line card553-3001-211 Standard 3.00 August 2005B-channels transmit user voice and data information at high speeds, while

Seite 314

NT6D70 SILC Line card Page 381 of 906Circuit Card Description and InstallationA logical terminal is any terminal that can communicate with the syste

Seite 315

Page 382 of 906 NT6D70 SILC Line card553-3001-211 Standard 3.00 August 2005The reset and sanity timer logic resets the MCU.The serial control interfa

Seite 316

NT6D70 SILC Line card Page 383 of 906Circuit Card Description and InstallationThe transceiver circuits provide four-wire full-duplex S/T bus interfa

Seite 317

Page 384 of 906 NT6D70 SILC Line card553-3001-211 Standard 3.00 August 2005

Seite 318 - Configuration

Page 385 of 906Circuit Card Description and Installation388NT6D71 UILC Line cardContentsThis section contains information on the following topics:Intr

Seite 319

Page 386 of 906 NT6D71 UILC Line card553-3001-211 Standard 3.00 August 2005Power consumptionPower consumption is +5 V at 1900 mA.Functional descripti

Seite 320

NT6D71 UILC Line card Page 387 of 906Circuit Card Description and InstallationThe serial control interface is an IPE bus that communicates with the

Seite 321 - NT5D97 faceplate

Page 388 of 906 NT6D71 UILC Line card553-3001-211 Standard 3.00 August 2005

Seite 322 - Figure 65

Page 389 of 906Circuit Card Description and Installation426NT6D80 MSDL cardContentsThis section contains information on the following topics:Introduct

Seite 323

Overview Page 39 of 906Circuit Card Description and InstallationCoder/Decoder circuitThe Coder/Decoder (CODEC) performs Analog to Digital (A/D) and

Seite 324

Page 390 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005that support the same functions. For example, three cards supported with the MS

Seite 325

NT6D80 MSDL card Page 391 of 906Circuit Card Description and InstallationFigure 82MSDL component layout553-5431S9 S10OnesTensPort 0Port 1Port 2Port

Seite 326 - Port definitions

Page 392 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Functional descriptionFigure 83 on page 393 illustrates the MSDL functional blo

Seite 327

NT6D80 MSDL card Page 393 of 906Circuit Card Description and InstallationFigure 83MSDL block diagramAddress Buffer and Decoding LogicControl and Da

Seite 328 - Cable requirements

Page 394 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Micro Processing Unit (MPU)The MPU, which is based on a Motorola 68020 processo

Seite 329

NT6D80 MSDL card Page 395 of 906Circuit Card Description and InstallationEquipment emulation mode – Configure an MSDL port to emulate DCE or DTE by

Seite 330 - 553-7385

Page 396 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Figure 84MSDL functional block diagramAML LoadwareCPU BusBoot Code& LoaderM

Seite 331 - NT8D7217 (A0617192)

NT6D80 MSDL card Page 397 of 906Circuit Card Description and InstallationData flowThe MSDL transmit interface, managed by the MSDL handler, sends da

Seite 332 - NTCK78AA (A0618294)

Page 398 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Card mixA system that exclusively uses MSDL cards can support up to 16 such car

Seite 333 - NTCK79AA (A0618296)

NT6D80 MSDL card Page 399 of 906Circuit Card Description and InstallationTable 148 lists the synchronous interface specifications and the means of c

Seite 334 - 553-7388

Page 4 of 906 Revision history 553-3001-211 Standard 3.00 August 2005

Seite 335 - 2.8, 4, 7 or 14 ft

Page 40 of 906 Overview553-3001-211 Standard 3.00 August 2005(nominal) ringing voltage power supply is used to prevent switching of the relay during

Seite 336 - 553-7387

Page 400 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Emulation mode Each port can be configured to emulate a DCE port or a DTE port

Seite 337 - Cable diagrams

NT6D80 MSDL card Page 401 of 906Circuit Card Description and InstallationTable 151 on page 402 lists RS-422 interface specifications for EIA circuit

Seite 338 - LED's

Page 402 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005supported circuit type. It also indicates whether the signal originates at the

Seite 339

NT6D80 MSDL card Page 403 of 906Circuit Card Description and Installation• A maximum of eight MSDL cards can be installed in a fully occupied module

Seite 340

Page 404 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005The internal power supply in each module provides DC power for the MSDL and oth

Seite 341

NT6D80 MSDL card Page 405 of 906Circuit Card Description and Installationsettings shown in this figure are an example of the different types of inte

Seite 342 - Dip switches for NT5D97AA/AB

Page 406 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Figure 85MSDL switch setting exampleS9 S10OnesTensPort 0Port 1Port 2Port 3Monit

Seite 343

NT6D80 MSDL card Page 407 of 906Circuit Card Description and InstallationInstalling the MSDL cardProcedure 16Installing the MSDL cardTo install an M

Seite 344

Page 408 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Cable requirementsThe MSDL card includes four high-density 26-pin (SCSI II) fem

Seite 345 - NT5D97AA/AB

NT6D80 MSDL card Page 409 of 906Circuit Card Description and InstallationFigure 86MSDL cablingI/OpanelI/OpanelQPC720MSDLESDI to I/O cable(NTND27AB—6

Seite 346

Overview Page 41 of 906Circuit Card Description and Installationvoltage protection between the TCM loop and the digital line interface circuit. It a

Seite 347 - NT5D97AD DIP switch settings

Page 410 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Note: The choices of cable to use with an MSDL card depend on what type of mode

Seite 348 - Figure 76

NT6D80 MSDL card Page 411 of 906Circuit Card Description and Installation5 Plug the DB15 male connector end of the cable into the J5 DB15 female con

Seite 349 - Trunk 0 switches

Page 412 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005MSDL planning formUse the following planning form to help sort and store inform

Seite 350 - Trunk 1 switches for NT5D97AD

NT6D80 MSDL card Page 413 of 906Circuit Card Description and InstallationMaintenanceRoutine maintenance consists of enabling and disabling MSDL card

Seite 351 - NT5D97AD

Page 414 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005A newly configured MSDL automatically enters the manually disabled state. An op

Seite 352 - MSDL external card

NT6D80 MSDL card Page 415 of 906Circuit Card Description and InstallationSystem disabledWhen the system disables the MSDL card (step 4 in Figure 87

Seite 353 - Architecture

Page 416 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005• Recovery Threshold The MSDL card was successfully enabled by the MSDL autorec

Seite 354 - Secondary

NT6D80 MSDL card Page 417 of 906Circuit Card Description and InstallationManually controlled maintenanceUse manual maintenance commands found in the

Seite 355 - Automatic clock recovery

Page 418 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Disabling the MSDLTo disable an MSDL card, enter DIS MSDL x.To disable the MSDL

Seite 356 - Clock configurations

NT6D80 MSDL card Page 419 of 906Circuit Card Description and InstallationManually isolating and correcting faultsProblems are due to configuration e

Seite 357

Page 42 of 906 Overview553-3001-211 Standard 3.00 August 2005the system controller to operate the digital line interface circuits during calls. The c

Seite 358

Page 420 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Previously operating MSDL cardsProblems that occur during normal operation usua

Seite 359

NT6D80 MSDL card Page 421 of 906Circuit Card Description and InstallationReplacing MSDL cardsAfter completing MSDL troubleshooting you may determine

Seite 360 - Clock Controller – Option 2

Page 422 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005Symptoms and actionsExplained here are some of the symptoms, diagnoses, and act

Seite 361 - Clock Controller – Option 3

NT6D80 MSDL card Page 423 of 906Circuit Card Description and InstallationSystem disabled actionsThese explain the causes of problems and the actions

Seite 362 - Clock Controller – Option 4

Page 424 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005using autorecovery. If a diagnostic program (overlay) is active, the downloadin

Seite 363

NT6D80 MSDL card Page 425 of 906Circuit Card Description and InstallationSYSTEM DISABLED—OVERLOADCause: The system received an excessive number of m

Seite 364

Page 426 of 906 NT6D80 MSDL card553-3001-211 Standard 3.00 August 2005SYSTEM DISABLED—FATAL ERRORCause: The MSDL card encountered a fatal error and c

Seite 365 - Configuring the NT5D97

Page 427 of 906Circuit Card Description and Installation526NT7D16 Data Access cardContent listThe following are the topics in this section:Introductio

Seite 366 - Testability and diagnostics

Page 428 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005IntroductionThe NT7D16 Data Access card (DAC) is a data interface card t

Seite 367

NT7D16 Data Access card Page 429 of 906Circuit Card Description and Installation• Wire test mode• Self diagnostics• Inbound modem pooling with any a

Seite 368

Overview Page 43 of 906Circuit Card Description and InstallationFigure 6Call connection sequence – near-end station receiving call553-AAA1113High-re

Seite 369 - NT5K21 XMFC/MFE card

Page 430 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Port modeThis lamp lights to indicate that the port indicated is in RS-4

Seite 370 - Forward and backward signals

NT7D16 Data Access card Page 431 of 906Circuit Card Description and InstallationFigure 88NT7D16 Data Access card faceplateSDRDDTRDSRDCDRICONNECTRS-4

Seite 371

Page 432 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Call Set-up abortThe user may abandon the call during the dialogue phase

Seite 372 - MFE signaling

NT7D16 Data Access card Page 433 of 906Circuit Card Description and InstallationNote: If this feature is active, and the port is connected to a DTE

Seite 373 - Sender and receiver mode

Page 434 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005CTS Clear To Send 5 3 —DSR Data Set Ready 6 4 —DCD Carrier Detect 8 5 —D

Seite 374

NT7D16 Data Access card Page 435 of 906Circuit Card Description and InstallationIndependent storage of dialing parametersTwo dialing parameters, DCD

Seite 375

Page 436 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005The fourth mode, gateway, is a subset of the modem mode and is not norma

Seite 376 - Physical specifications

NT7D16 Data Access card Page 437 of 906Circuit Card Description and Installation2 (DTE) OFF“Host On”(RI)ONForcedOFFNot HotlineModem Pool inbound and

Seite 377

Page 438 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 20056 (DTE) ON“KBD On”(No RI)ONForcedOFFNot HotlineGateway inbound and outbo

Seite 378

NT7D16 Data Access card Page 439 of 906Circuit Card Description and Installation10 (DCE) OFF“Host On”(prompts off)ONForcedOFFNot HotlineHost similar

Seite 379 - NT6D70 SILC Line card

Page 44 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 7Call connection sequence – near-end originating call553-AAA1114High-resistancelo

Seite 380

Page 440 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Selecting the proper mode for Modem connectivitySelect modes 0, 1, 2, an

Seite 381 - Micro Controller Unit (MCU)

NT7D16 Data Access card Page 441 of 906Circuit Card Description and InstallationIn the case of outbound modem pooling, the DAC answers the data call

Seite 382 - S/T interface logic

Page 442 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 0This mode should be selected when the DAC is connected to a modem,

Seite 383

NT7D16 Data Access card Page 443 of 906Circuit Card Description and InstallationAuto-dial capability This feature is required when the modem is used

Seite 384

Page 444 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Programing DAC for mode 0 in service change LD11When used for inbound or

Seite 385 - NT6D71 UILC Line card

NT7D16 Data Access card Page 445 of 906Circuit Card Description and InstallationFigure 90DAC to Modem Pool connectivitySystemOutbound huntingInbound

Seite 386

Page 446 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 1This mode should be selected when the DAC is connected to an auto-

Seite 387 - U interface logic

NT7D16 Data Access card Page 447 of 906Circuit Card Description and InstallationPrograming DAC for mode 1 in service change LD11The DAC must be conf

Seite 388

Page 448 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Note: If Call Detail Recording (CDR) is required, use separate outbound

Seite 389 - NT6D80 MSDL card

NT7D16 Data Access card Page 449 of 906Circuit Card Description and Installation• The equipment can monitor the DTR lead (optional, depending on the

Seite 390

Overview Page 45 of 906Circuit Card Description and InstallationMessage waitingLine cards that are equipped with the message waiting feature receive

Seite 391 - 553-5431

Page 450 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 4This mode should be selected when the DAC is connected to a gatewa

Seite 392

NT7D16 Data Access card Page 451 of 906Circuit Card Description and InstallationIn the outbound operation, the DAC drives the DTR lead OFF until ano

Seite 393 - MSDL block diagram

Page 452 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 5This mode should be selected when the DAC is connected to an auto-

Seite 394 - Serial interface

NT7D16 Data Access card Page 453 of 906Circuit Card Description and InstallationPrograming DAC for mode 6 in service change LD 11When used for inbou

Seite 395 - MSDL operations

Page 454 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005go ON for 2 seconds and then OFF for 4 seconds until the call is answere

Seite 396 - 553-5433

NT7D16 Data Access card Page 455 of 906Circuit Card Description and InstallationDynamic control of DTR This feature is required only if the host mus

Seite 397 - Engineering guidelines

Page 456 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Programing DAC for mode 9 in service change LD 11The DAC must be configu

Seite 398 - Port specifications

NT7D16 Data Access card Page 457 of 906Circuit Card Description and InstallationThis mode should be selected when the DAC is connected to a host and

Seite 399

Page 458 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005unless the DTR lead is driven ON by the terminal. Any terminal that driv

Seite 400

NT7D16 Data Access card Page 459 of 906Circuit Card Description and InstallationMode 13This mode should be selected when the DAC is connected to a t

Seite 401

Page 46 of 906 Overview553-3001-211 Standard 3.00 August 2005causes the line card to revert the battery and ground signals to the normal state to sig

Seite 402 - Implementation guidelines

Page 460 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 15This mode provides a “virtual leased line” and the meaning of the

Seite 403

NT7D16 Data Access card Page 461 of 906Circuit Card Description and InstallationNote: If AUTB is set to ON, the BAUD parameter is not prompted. If A

Seite 404

Page 462 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Outbound modem pooling:Local DM user calls to the outbound modem access

Seite 405

NT7D16 Data Access card Page 463 of 906Circuit Card Description and InstallationMode 1 Inbound Hotline modem poolsInbound Hotline modem pooling:Most

Seite 406 - MSDL switch setting example

Page 464 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 3 Inbound Hotline modem pools (with forced DTR)Use this mode with H

Seite 407 - Installing the MSDL card

NT7D16 Data Access card Page 465 of 906Circuit Card Description and InstallationCall disconnection (DAC):DAC drops DTR if the local DM user drops th

Seite 408

Page 466 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 6 Inbound and Outbound Gateway access (with forced DTR)Inbound and

Seite 409 - 553-5845

NT7D16 Data Access card Page 467 of 906Circuit Card Description and InstallationMode 8 Host access for call origination and answeringHost answering

Seite 410 - Cable installation

Page 468 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Call disconnect ion (DAC):DAC drops DSR, DCD, and CTS if the local DM us

Seite 411 - I/O panel connections

NT7D16 Data Access card Page 469 of 906Circuit Card Description and InstallationMode 10 Host access for call origination and answering (with forced

Seite 412 - MSDL planning form

Overview Page 47 of 906Circuit Card Description and InstallationFigure 8Battery reversal answer and disconnect supervision sequence SystemHigh-resi

Seite 413 - Maintenance

Page 470 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Mode 12 Terminal access for call origination and answeringTerminal answe

Seite 414 - 553-5435

NT7D16 Data Access card Page 471 of 906Circuit Card Description and InstallationCall disconnection (terminal): Terminal toggles DTR from ON to OFF (

Seite 415 - DIS MSDL x to disable

Page 472 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Keyboard dialingKeyboard dialing is an interactive dialogue mode between

Seite 416 - System controlled maintenance

NT7D16 Data Access card Page 473 of 906Circuit Card Description and Installation• Autoparity to ensure that the keyboard dialing menu is readable on

Seite 417

Page 474 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005PromptsCall processing prompts are in upper case letters only. Other pro

Seite 418

NT7D16 Data Access card Page 475 of 906Circuit Card Description and InstallationKeyboard Autobaud is allowed after the call is placed in off-line mo

Seite 419

Page 476 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Whenever a Primary command is expected, the user may enter the Parity co

Seite 420

NT7D16 Data Access card Page 477 of 906Circuit Card Description and InstallationAutodial (A)The Autodial command allows the user to dial a predefine

Seite 421 - Replacing MSDL cards

Page 478 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005if the access code is less than the maximum number of digits allowed for

Seite 422 - Symptoms and actions

NT7D16 Data Access card Page 479 of 906Circuit Card Description and InstallationBy entering S on the keyboard, you enter the Speed Call Modify menu.

Seite 423 - System disabled actions

Page 48 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 9Hook flash disconnect supervision sequenceHigh-resistanceloopLine card unit idle

Seite 424

Page 480 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005of rings. Respond to the following prompts to enable or disable the Manu

Seite 425

NT7D16 Data Access card Page 481 of 906Circuit Card Description and InstallationBy entering L on the keyboard, you enter the Long Break Detect Modif

Seite 426

Page 482 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Note: If you hang up the call, or give an abandon command, Ring Again is

Seite 427 - NT7D16 Data Access card

NT7D16 Data Access card Page 483 of 906Circuit Card Description and InstallationAgain prompt within a software determined time period, Ring Again is

Seite 428 - Features

Page 484 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Not in serviceWhen the DAC attempts a call to a DN that is not supported

Seite 429 - Controls and indicators

NT7D16 Data Access card Page 485 of 906Circuit Card Description and InstallationHayes dialingLike keyboard dialing, Hayes dialing is an interactive

Seite 430 - Dialing operations

Page 486 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005— the DTE mode, and RI has cycled the appropriate number of times and DC

Seite 431 - Figure 88

NT7D16 Data Access card Page 487 of 906Circuit Card Description and InstallationResult codes and messagesEach input record generates a result code w

Seite 432 - Make Port Busy on loss of DTR

Page 488 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Baud rate detectionEvery command line begins with Baud rate detection. T

Seite 433 - Wire test mode

NT7D16 Data Access card Page 489 of 906Circuit Card Description and InstallationNote: The parity determined here overrides the parity downloaded fro

Seite 434

Overview Page 49 of 906Circuit Card Description and InstallationCall operation will be described by categorizing the operation into the following ma

Seite 435 - Operating modes

Page 490 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005For the purposes of this document, when illustrating the prompt/response

Seite 436

NT7D16 Data Access card Page 491 of 906Circuit Card Description and InstallationAll S registers may be changed with the exception of S1, the Ring co

Seite 437

Page 492 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005You can view any of the S registers by issuing the following display com

Seite 438

NT7D16 Data Access card Page 493 of 906Circuit Card Description and InstallationReset Hayes parametersAll of the Hayes dialing parameters and S regi

Seite 439

Page 494 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005V 1 Result codes sent in Verbose formatX 1 Features selection 0 - 8, 10

Seite 440

NT7D16 Data Access card Page 495 of 906Circuit Card Description and InstallationOutbound callsThe DAC supports two types of outbound data calls:• po

Seite 441

Page 496 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Issuing the On Hook command while the call is still ringing disconnects

Seite 442 - DAC to modem connectivity

NT7D16 Data Access card Page 497 of 906Circuit Card Description and InstallationIn the following example, <GT> is the Guard Time and <EC>

Seite 443

Page 498 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005System parametersSystem parameters downloaded by the switch include the

Seite 444

NT7D16 Data Access card Page 499 of 906Circuit Card Description and Installation— Hotline (call the Autodial number upon connection)• Wire test— Dis

Seite 445 - 553-AAA1126

Page 5 of 906Circuit Card Description and Installation18ContentsLIst of procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 19About this do

Seite 446

Page 50 of 906 Overview553-3001-211 Standard 3.00 August 2005Outgoing callsDuring outgoing calls from the terminal equipment, a channel is seized whe

Seite 447

Page 500 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005—DCE—DTE• Equipment type— Terminal (send prompts/replies)— Host (suppres

Seite 448

NT7D16 Data Access card Page 501 of 906Circuit Card Description and InstallationFigure 95Operating mode selection—RS422PRM = OffPRM = OnOPE YESHostV

Seite 449

Page 502 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Figure 96Operating mode selection—RS-232-COperate Mode?DEM = DTEPRM = On

Seite 450 - DAC to Gateway connectivity

NT7D16 Data Access card Page 503 of 906Circuit Card Description and InstallationNote: Warning Tone Denied (WTD) defaults if DTA is entered.• If the

Seite 451 - 553-AAA1127

Page 504 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Power supplyBe sure that all power requirements are met before installin

Seite 452

NT7D16 Data Access card Page 505 of 906Circuit Card Description and InstallationEnvironmentalThe DAC functions fully when operating within the follo

Seite 453

Page 506 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Large SystemIn Large Systems, the DAC is fully supported in IPE modules.

Seite 454 - DAC to Host connectivity

NT7D16 Data Access card Page 507 of 906Circuit Card Description and InstallationAn upgraded backplane has three shrouds for each card slot. A backpl

Seite 455

Page 508 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Figure 97NT7D16 Data Access Card port connectorsNote: Insert only one op

Seite 456

NT7D16 Data Access card Page 509 of 906Circuit Card Description and InstallationCablingSeveral cabling schemes are possible for both AILC and RILC m

Seite 457

Overview Page 51 of 906Circuit Card Description and Installation• In order to detect distant end disconnect for calls terminating on the lineside T1

Seite 458 - DAC to Terminal connectivity

Page 510 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Figure 98Cabling to the data equipment SystemI/O connectorMDF(12 connec

Seite 459

NT7D16 Data Access card Page 511 of 906Circuit Card Description and InstallationFigure 99 shows a connection through an RJ-11 or RJ-45 jack located

Seite 460 - Mode selection baud rates

Page 512 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Note: Use an octopus cable that follows the pinout of the DAC, such as Q

Seite 461

NT7D16 Data Access card Page 513 of 906Circuit Card Description and InstallationFigure 101Octopus cablingMDFTxDRxDGNDDTRCTSDSRDCDRITxDRxDGNDDTRCTSDS

Seite 462

Page 514 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Backplane pinout and signalingTwo 40-pin, and two 20-pin edge connectors

Seite 463

NT7D16 Data Access card Page 515 of 906Circuit Card Description and Installation7R 7 O-R DSR1 68T 33 R-G RI1 228R 8 G-R CTS1 59T 34 R-BR UNIT 2 TD2

Seite 464

Page 516 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Table 171RS-232-C and RS-422 pinouts for last three DAC ports (Part 1 of

Seite 465

NT7D16 Data Access card Page 517 of 906Circuit Card Description and InstallationConfiguring the Data Access cardLD 11 must be configured to accept t

Seite 466

Page 518 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005required. The defaults are bracketed, and may be issued by Carriage Retu

Seite 467

NT7D16 Data Access card Page 519 of 906Circuit Card Description and InstallationHOT (OFF) ON HotlineIf HOT = ON, then AUTB = OFFAUT (ON) OFF Automat

Seite 468

Page 52 of 906 Overview553-3001-211 Standard 3.00 August 2005Ground Start ModeIn ground start mode, the A and B bits have the following meaning:Trans

Seite 469

Page 520 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005DLNG (ENG) FRN Data port language, where:ENG = EnglishFRN = Quebec Frenc

Seite 470

NT7D16 Data Access card Page 521 of 906Circuit Card Description and InstallationPrinting the card parameters (LD 20)By responding R232, R422, or DAC

Seite 471

Page 522 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Connecting Apple Macintosh to the DACThe Apple Macintosh can be connecte

Seite 472 - Keyboard dialing

NT7D16 Data Access card Page 523 of 906Circuit Card Description and InstallationFigure 102Macintosh to DAC connection—9-pin subminiature DFigure 103

Seite 473 - Initiating conditions

Page 524 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Large System and CS 1000M HG upgradeThe DAC can be installed directly in

Seite 474 - Autobaud

NT7D16 Data Access card Page 525 of 906Circuit Card Description and InstallationSegment 21 Leave cable K as is in slot L8.2 Move cable end L-3 to L9

Seite 475 - Dialing operation

Page 526 of 906 NT7D16 Data Access card553-3001-211 Standard 3.00 August 2005Be sure to re-label the MDF to show that the module has been upgraded to

Seite 476 - Primary commands

Page 527 of 906Circuit Card Description and Installation544NT8D02 and NTDK16 Digital Line cardsContentsThis section contains information on the follow

Seite 477

Page 528 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005The Digital Line card provides 16 voice and 16 data communi

Seite 478

NT8D02 and NTDK16 Digital Line cards Page 529 of 906Circuit Card Description and InstallationFigure 104Digital line card – faceplate553-6160DgtlLCNT

Seite 479

Overview Page 53 of 906Circuit Card Description and InstallationIncoming CallsIncoming calls to terminal equipment that is connected to the lineside

Seite 480 - Answer feature

Page 530 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005Functional descriptionNT8D02 Digital Line cardThe NT8D02 di

Seite 481 - Ring Again

NT8D02 and NTDK16 Digital Line cards Page 531 of 906Circuit Card Description and InstallationFigure 105Digital line card – block diagramDigitallinei

Seite 482

Page 532 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005NTDK16 Digital Line cardThe NTDK16 digital line card is equ

Seite 483

NT8D02 and NTDK16 Digital Line cards Page 533 of 906Circuit Card Description and InstallationFigure 106NTDK16 DLC

Seite 484 - No response from the system

Page 534 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005lines carry multiplexed PCM voice, data, and signaling info

Seite 485 - Hayes dialing

NT8D02 and NTDK16 Digital Line cards Page 535 of 906Circuit Card Description and InstallationCard control functionsControl functions are provided by

Seite 486 - Input requirements

Page 536 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005the sanity timer every 1.2 seconds. If the timer is not pro

Seite 487 - Result codes and messages

NT8D02 and NTDK16 Digital Line cards Page 537 of 906Circuit Card Description and InstallationDigital line interface specificationsTable 173 provides

Seite 488 - Parity detection

Page 538 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005Power requirementsThe digital line card needs +15V DC over

Seite 489

NT8D02 and NTDK16 Digital Line cards Page 539 of 906Circuit Card Description and InstallationEnvironmental specificationsTable 175 shows the environ

Seite 490 - S registers

Page 54 of 906 Overview553-3001-211 Standard 3.00 August 2005Note: By default, the SAL feature opens the tip side for 750 m/s in loop start operation

Seite 491

Page 540 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 200516A Line 4, Ring 16B Line 4, Tip17A Line 5, Ring 17B Line 5

Seite 492

NT8D02 and NTDK16 Digital Line cards Page 541 of 906Circuit Card Description and InstallationConfigurationThis section outlines the procedures for c

Seite 493 - Reset Hayes parameters

Page 542 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005Figure 107Digital line card – jumper block and switch locat

Seite 494

NT8D02 and NTDK16 Digital Line cards Page 543 of 906Circuit Card Description and InstallationFigure 108Digital line card – jumper block and switch l

Seite 495 - Inbound calls

Page 544 of 906 NT8D02 and NTDK16 Digital Line cards553-3001-211 Standard 3.00 August 2005

Seite 496 - Off Line mode

Page 545 of 906Circuit Card Description and Installation546NT8D03 Analog Line cardOverviewThe NT8D03 Analog Line card provides an interface for up to

Seite 497 - Specifications

Page 546 of 906 NT8D03 Analog Line card553-3001-211 Standard 3.00 August 2005

Seite 498 - Operating parameters

Page 547 of 906Circuit Card Description and Installation564NT8D09 Analog Message WaitingLine cardContentsThis section contains information on the foll

Seite 499

Page 548 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Note: A maximum of four NT8D09 Analog Message Waiting Li

Seite 500 - System database requirements

NT8D09 Analog Message Waiting Line card Page 549 of 906Circuit Card Description and InstallationPhysical descriptionThe circuitry is mounted on a 31

Seite 501 - Figure 95

Overview Page 55 of 906Circuit Card Description and InstallationGround Start RestrictionsIf the lineside T1 card is used in ground start mode, certa

Seite 502 - Figure 96

Page 550 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Figure 109Analog message waiting line card – faceplate55

Seite 503

NT8D09 Analog Message Waiting Line card Page 551 of 906Circuit Card Description and InstallationThe NT8D09 Analog Message Waiting Line card also pro

Seite 504 - Power supply

Page 552 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Figure 110Analog message waiting line card – block diagr

Seite 505 - Cabinet system

NT8D09 Analog Message Waiting Line card Page 553 of 906Circuit Card Description and InstallationCard interfacesThe analog message waiting line card

Seite 506 - System compatibility

Page 554 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Card control functionsControl functions are provided by

Seite 507 - Port configuration

NT8D09 Analog Message Waiting Line card Page 555 of 906Circuit Card Description and InstallationAnalog line interfaceInput impedanceThe impedance at

Seite 508 - Figure 97

Page 556 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Table 179 provides a technical summary of the analog mes

Seite 509

NT8D09 Analog Message Waiting Line card Page 557 of 906Circuit Card Description and InstallationPower requirementsTable 180 provides the power requi

Seite 510 - Cabling to the data equipment

Page 558 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Overload levelSignal levels exceeding +7 dBm applied to

Seite 511 - RJ-11 or RJ-45 jacks

NT8D09 Analog Message Waiting Line card Page 559 of 906Circuit Card Description and InstallationInstallation and Configuration (553-3021-210) for ca

Seite 512 - Patch panel layout

Page 56 of 906 Overview553-3001-211 Standard 3.00 August 2005Distant end disconnect restrictionsIf the SAL feature is not available in the CS 1000 Re

Seite 513 - 553-5022

Page 560 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005Figure 111Analog message waiting line card – typical cro

Seite 514

NT8D09 Analog Message Waiting Line card Page 561 of 906Circuit Card Description and InstallationConfigurationThis section outlines the procedures fo

Seite 515

Page 562 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005the system for port-to-port loss. See Software Input/Out

Seite 516

NT8D09 Analog Message Waiting Line card Page 563 of 906Circuit Card Description and InstallationFigure 112Analog message waiting line card – jumper

Seite 517 - DAC administration (LD 11)

Page 564 of 906 NT8D09 Analog Message Waiting Line card553-3001-211 Standard 3.00 August 2005

Seite 518 - (<CR>)

Page 565 of 906Circuit Card Description and Installation626NT8D14 Universal Trunk cardContentsThis section contains information on the following topic

Seite 519

Page 566 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005The NT8D14 Universal Trunk card interfaces eight analog trunk lines

Seite 520

NT8D14 Universal Trunk card Page 567 of 906Circuit Card Description and InstallationTable 184 lists the signaling and trunk types supported by the N

Seite 521

Page 568 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005The faceplate of the card is equipped with a red Light Emitting Diod

Seite 522 - Upgrading systems

NT8D14 Universal Trunk card Page 569 of 906Circuit Card Description and InstallationFigure 113Universal trunk card – faceplateSUnivTrkNT8D14Rlse 0xC

Seite 523 - 553-AAA113

Overview Page 57 of 906Circuit Card Description and InstallationVoice frequency audio levelThe digital pad for lineside T1 card audio level is fixed

Seite 524

Page 570 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Functional descriptionFigure 114 shows a block diagram of the major

Seite 525

NT8D14 Universal Trunk card Page 571 of 906Circuit Card Description and InstallationCard interfacesThe NT8D14 Universal Trunk card passes voice and

Seite 526

Page 572 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Card control functionsControl functions are provided by a microcontr

Seite 527

NT8D14 Universal Trunk card Page 573 of 906Circuit Card Description and Installationprovides the means for analog loop terminations to establish, su

Seite 528

Page 574 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005receive digits, it returns a dial tone. Outward address signaling is

Seite 529 - Card lock latch

NT8D14 Universal Trunk card Page 575 of 906Circuit Card Description and InstallationFigure 116Loop start call connection sequence – incoming call fr

Seite 530

Page 576 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005For trunks not equipped with answer supervision, the PIP class of se

Seite 531 - Figure 105

NT8D14 Universal Trunk card Page 577 of 906Circuit Card Description and InstallationFigure 118Ground start call connection sequence – incoming call

Seite 532 - Digital line interfaces

Page 578 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Ground start operationGround start operation is configured in softwa

Seite 533 - NTDK16 DLC

NT8D14 Universal Trunk card Page 579 of 906Circuit Card Description and InstallationA trunk identified as possibly reverse-wired is switched by the

Seite 534

Page 58 of 906 Overview553-3001-211 Standard 3.00 August 2005Nortel has tested line protection devices from three manufacturers. See Table 6. Each ma

Seite 535

Page 580 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 120Ground start call connection sequence – incoming call from

Seite 536

NT8D14 Universal Trunk card Page 581 of 906Circuit Card Description and Installationreverse-wired trunk becomes correctly wired, the first subsequen

Seite 537

Page 582 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 121Ground start call states – outgoing call to CO/FX/WATSSyst

Seite 538

NT8D14 Universal Trunk card Page 583 of 906Circuit Card Description and InstallationFigure 122Ground start call connection sequence – outgoing call

Seite 539

Page 584 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Direct inward dial operationIncoming callsAn incoming call from the

Seite 540

NT8D14 Universal Trunk card Page 585 of 906Circuit Card Description and InstallationFigure 123DID trunk, loop DR call states – incoming call from CO

Seite 541

Page 586 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 124DID trunk, loop DR call connection sequence – incoming cal

Seite 542 - 553-6161

NT8D14 Universal Trunk card Page 587 of 906Circuit Card Description and InstallationFigure 125Two-way, loop DR, TIE trunk call states – incoming cal

Seite 543

Page 588 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 126Two-way, loop DR, TIE trunk call connection sequence – inc

Seite 544

NT8D14 Universal Trunk card Page 589 of 906Circuit Card Description and InstallationOutgoing callsIn an outgoing call configuration, the NT8D14 Univ

Seite 545 - NT8D03 Analog Line card

Overview Page 59 of 906Circuit Card Description and Installationgrounding connection requirements as described in System installation (553-3001-210)

Seite 546

Page 590 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 127Two-way, loop DR, TIE trunk call states – outgoing call to

Seite 547 - Line card

NT8D14 Universal Trunk card Page 591 of 906Circuit Card Description and InstallationFigure 128Two-way, loop DR, TIE trunk call connection sequence –

Seite 548

Page 592 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 129Two-way, loop DR, TIE trunk call states – outgoing call to

Seite 549

NT8D14 Universal Trunk card Page 593 of 906Circuit Card Description and InstallationFigure 130Two-way, loop DR, TIE trunk call connection sequence –

Seite 550 - 553-6165

Page 594 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Senderized operation for DID and two-way loop DR trunksIncoming call

Seite 551

NT8D14 Universal Trunk card Page 595 of 906Circuit Card Description and InstallationFigure 131Two-way, loop DR, TIE trunk call states – incoming cal

Seite 552 - 553-6168

Page 596 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 132Two-way, loop DR, TIE trunk call states – incoming call th

Seite 553 - Line interface units

NT8D14 Universal Trunk card Page 597 of 906Circuit Card Description and InstallationNote: Pseudo-answer supervision is provided by near-end at expir

Seite 554

Page 598 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 133Two-way, loop DR, TIE trunk call states – outgoing call th

Seite 555

NT8D14 Universal Trunk card Page 599 of 906Circuit Card Description and InstallationFigure 134Two-way, loop OAID, TIE trunk call states – incoming c

Seite 556

Page 6 of 906 Contents 553-3001-211 Standard 3.00 August 2005Acceptance tests . . . . . . . . . . . . . . . . . . . . . . . . . . 89Contents . . .

Seite 557

Page 60 of 906 Overview553-3001-211 Standard 3.00 August 2005Each of the trunk cards was designed to fit a specific system need. Use Table 7 to help

Seite 558

Page 600 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 135Two-way, loop OAID, TIE trunk call connection sequence – i

Seite 559

NT8D14 Universal Trunk card Page 601 of 906Circuit Card Description and InstallationFigure 136Two-way, loop OAID, TIE trunk call states – outgoing c

Seite 560 - 553-AAA1131

Page 602 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 137Two-way, loop OAID, TIE trunk call connection sequence – o

Seite 561

NT8D14 Universal Trunk card Page 603 of 906Circuit Card Description and InstallationRecorded announcement trunk operationNote: Refer to “Multi-Chann

Seite 562

Page 604 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 138Connecting RAN equipment to the NT8D14 Universal Trunk car

Seite 563 - 553-6166

NT8D14 Universal Trunk card Page 605 of 906Circuit Card Description and InstallationRAN modes of operationFigure 139 on page 606 shows the relations

Seite 564

Page 606 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005The Route Data Block LD 16 is used to configure a RAN route in Multi

Seite 565

NT8D14 Universal Trunk card Page 607 of 906Circuit Card Description and InstallationTrunk members are provisioned in the Trunk Data Block LD 14.Refe

Seite 566

Page 608 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Call routing to RAN trunksCS 1000 Release 4.5 software controls reco

Seite 567

NT8D14 Universal Trunk card Page 609 of 906Circuit Card Description and InstallationElectrical specificationsTable 185 gives the electrical characte

Seite 568

Overview Page 61 of 906Circuit Card Description and InstallationThe universal trunk card also supports Music, Automatic Wake Up, and Direct Inward S

Seite 569 - Figure 113

Page 610 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Power requirementsPower to the NT8D14 Universal Trunk card is provid

Seite 570

NT8D14 Universal Trunk card Page 611 of 906Circuit Card Description and InstallationForeign and surge voltage protectionThe NT8D14 Universal Trunk c

Seite 571

Page 612 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005The class-of-service determines the operation of the switchable PADs

Seite 572

NT8D14 Universal Trunk card Page 613 of 906Circuit Card Description and InstallationThe insertion loss from IPE ports to IPE ports is as follows:Tab

Seite 573

Page 614 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Connector pin assignmentsThe universal trunk card connects the eight

Seite 574 - Note 3:

NT8D14 Universal Trunk card Page 615 of 906Circuit Card Description and InstallationConfigurationThe trunk type for each unit on the card as well as

Seite 575 - Figure 116

Page 616 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005 Table 190Jumper strap settings – factory standard (NT8D14BA, NT8D1

Seite 576 - Administration program LD 14

NT8D14 Universal Trunk card Page 617 of 906Circuit Card Description and InstallationTable 191Jumper strap settings – extended range (NT8D14BA, NT8D1

Seite 577 - Figure 118

Page 618 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Jumper strap settingsFor most applications, the jumper strap setting

Seite 578 - Ground start operation

NT8D14 Universal Trunk card Page 619 of 906Circuit Card Description and Installation• DID trunks exceeding a loop resistance of 600 ohms• RAN trunks

Seite 579 - CO / FX / WATS (far) end

Page 62 of 906 Overview553-3001-211 Standard 3.00 August 20053 Install the cable that connects the backplane connector on the IPE module to the modul

Seite 580 - Figure 120

Page 620 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Figure 140Universal trunk card – jumper locations (for NT8D14BA, NT8

Seite 581

NT8D14 Universal Trunk card Page 621 of 906Circuit Card Description and Installation Table 193Trunk types – termination impedance and balance networ

Seite 582

Page 622 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005Port-to-port loss configurationLoss parameters are selected on the N

Seite 583 - Figure 122

NT8D14 Universal Trunk card Page 623 of 906Circuit Card Description and Installationtrunks. The class of service determines the operation of the swi

Seite 584 - Direct inward dial operation

Page 624 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005ApplicationsThe optional applications, features, and signaling arran

Seite 585 - CO (far) end

NT8D14 Universal Trunk card Page 625 of 906Circuit Card Description and InstallationFigure 141Connecting paging equipment to the NT8D14 Universal Tr

Seite 586 - Figure 124

Page 626 of 906 NT8D14 Universal Trunk card553-3001-211 Standard 3.00 August 2005

Seite 587 - Figure 125

Page 627 of 906Circuit Card Description and Installation666NT8D15 E&M Trunk cardContentsThis section contains information on the following topics:

Seite 588 - 553-AAA1140

Page 628 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Note: In Cabinet systems equipped with Meridian Mail, the Universal Tr

Seite 589

NT8D15 E&M Trunk card Page 629 of 906Circuit Card Description and InstallationPhysical descriptionThe line interface and common multiplexing cir

Seite 590 - Figure 127

Overview Page 63 of 906Circuit Card Description and InstallationOperationThis section describes how trunk cards fit into the CS 1000S, CS 1000M, and

Seite 591 - 553-AAA1142

Page 630 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 142E&M trunk card – faceplateSE & MDict TrkNT8D15Rlse 0

Seite 592 - Figure 129

NT8D15 E&M Trunk card Page 631 of 906Circuit Card Description and InstallationFunctional descriptionThe NT8D15 E&M Trunk card serves various

Seite 593

Page 632 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005• Software control of A/µ-Law mode.• Software control of digit collect

Seite 594

NT8D15 E&M Trunk card Page 633 of 906Circuit Card Description and InstallationCard interfacesThe E&M trunk card passes voice and signaling d

Seite 595 - Figure 131

Page 634 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Trunk circuit featuresTrunk unit functionsThe functions provided by ea

Seite 596 - Figure 132

NT8D15 E&M Trunk card Page 635 of 906Circuit Card Description and InstallationFigure 144E&M Type I signalingEE&M trunk cardExternal sign

Seite 597

Page 636 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 145E&M Type II signalingÐ 48VSGEMSBÐ 48VSGEPPMSB553-6259Not

Seite 598

NT8D15 E&M Trunk card Page 637 of 906Circuit Card Description and InstallationFigure 1464-wire DX signalingTip BT1J3J5T2 (Note 2)Ring BabTip ARi

Seite 599 - Figure 134

Page 638 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 147Paging trunk operationTypical customer-provided externalequi

Seite 600 - Figure 135

NT8D15 E&M Trunk card Page 639 of 906Circuit Card Description and InstallationCard control functionsControl functions are provided by a microcon

Seite 601 - Figure 136

Page 64 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 11Typical IPE trunk card architectureInput/outputinterfacecontrolCodecPCMMicro-co

Seite 602 - Figure 137

Page 640 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Signaling interfaceAll signaling messages for the trunk are three byte

Seite 603

NT8D15 E&M Trunk card Page 641 of 906Circuit Card Description and Installation• monitor signals from the trunk interface and generate a message

Seite 604 - Figure 138

Page 642 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Idle stateFor E&M signaling, in the idle state the M lead is groun

Seite 605

NT8D15 E&M Trunk card Page 643 of 906Circuit Card Description and InstallationFigure 149E&M Type I signaling patterns – originating party re

Seite 606 - RTYP = MLSS

Page 644 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 150E&M Type I signaling patterns – originating party releas

Seite 607

NT8D15 E&M Trunk card Page 645 of 906Circuit Card Description and InstallationIncoming callsThe far-end initiates calls as follows:• The ground

Seite 608

Page 646 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005for a tandem connection where the originating end is senderized and th

Seite 609

NT8D15 E&M Trunk card Page 647 of 906Circuit Card Description and InstallationFigure 151E&M Type II signaling patterns – originating party r

Seite 610

Page 648 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 152E&M Type II signaling patterns – originating party relea

Seite 611 - PAD switching

NT8D15 E&M Trunk card Page 649 of 906Circuit Card Description and InstallationTable 198 and Table 199 show call-connection and take-down sequenc

Seite 612

Overview Page 65 of 906Circuit Card Description and InstallationThe switch communicates with IPE modules over two separate interfaces. Voice and sig

Seite 613

Page 650 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Far-end on hook first Current flow HighNetwork taken down and trunk id

Seite 614

NT8D15 E&M Trunk card Page 651 of 906Circuit Card Description and InstallationNear end on hook first, network taken down Current flow LowFar end

Seite 615

Page 652 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Note: * – CO ground start: the trunk is idled and the network taken do

Seite 616

NT8D15 E&M Trunk card Page 653 of 906Circuit Card Description and InstallationEffective loss See pad table (Table 209 on page 662)See pad table

Seite 617

Page 654 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Power requirementsTable 204 lists the power requirements for the E&

Seite 618

NT8D15 E&M Trunk card Page 655 of 906Circuit Card Description and InstallationConnector pin assignmentsThe E&M trunk card brings the four an

Seite 619 - Service change entries

Page 656 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Table 207E&M trunk card – backplane pinouts for 4-wire modesTrunk

Seite 620

NT8D15 E&M Trunk card Page 657 of 906Circuit Card Description and InstallationFigure 153E&M trunk card – typical cross connection example553

Seite 621

Page 658 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005ConfigurationEach of the four trunk circuits on the E&M trunk card

Seite 622

NT8D15 E&M Trunk card Page 659 of 906Circuit Card Description and InstallationFigure 154E&M trunk card – jumper locations553-6200

Seite 623

Page 66 of 906 Overview553-3001-211 Standard 3.00 August 2005DS-30X loopsThe interfaces provided by the line and trunk cards connect to conventional

Seite 624

Page 660 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Table 208E&M trunk card – jumper strap settingsJumper(Note 1)Mode

Seite 625 - Figure 141

NT8D15 E&M Trunk card Page 661 of 906Circuit Card Description and InstallationSoftware service entriesThe trunk type is selected by making servi

Seite 626

Page 662 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005trunks. The class of service determines the operation of the switchabl

Seite 627

NT8D15 E&M Trunk card Page 663 of 906Circuit Card Description and InstallationFigure 155Pad orientationAnalog553-AAA1156SystemXMTAnalogRECRECPor

Seite 628

Page 664 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005ApplicationsThe optional applications, features and signaling arrangem

Seite 629

NT8D15 E&M Trunk card Page 665 of 906Circuit Card Description and InstallationTable 210 shows the insertion loss from IPE port to IPE port. Pagi

Seite 630 - Figure 142

Page 666 of 906 NT8D15 E&M Trunk card553-3001-211 Standard 3.00 August 2005Figure 156Paging trunk operationTypical customer-provided externalequi

Seite 631

Page 667 of 906Circuit Card Description and Installation680NT8D41AA Serial Data Interface Paddle BoardContentsThis section contains information on the

Seite 632 - Figure 143

Page 668 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005• NT6D39 CPU/Network module• NT9D11 Core/Network mod

Seite 633

NT8D41AA Serial Data Interface Paddle Board Page 669 of 906Circuit Card Description and InstallationFigure 157NT8D41AA SDI paddle boardOption switch

Seite 634 - Trunk circuit features

Overview Page 67 of 906Circuit Card Description and Installationsignaling data to the line card, it is sent as a 24-bit word divided among 24 succes

Seite 635 - E&M Type I signaling

Page 670 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005Functional descriptionThe NT8D41AA SDI paddle board

Seite 636 - E&M Type II signaling

NT8D41AA Serial Data Interface Paddle Board Page 671 of 906Circuit Card Description and Installationa socket in the CPU area of the backplane allows

Seite 637 - 4-wire DX signaling

Page 672 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005Configuring the SDI paddle boardConfiguring the SDI

Seite 638 - Paging trunk operation

NT8D41AA Serial Data Interface Paddle Board Page 673 of 906Circuit Card Description and InstallationOption switch settingsAddress Address select swi

Seite 639

Page 674 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005DTE/DCE/Fiber modeEach serial port can be configured

Seite 640 - Signaling interface

NT8D41AA Serial Data Interface Paddle Board Page 675 of 906Circuit Card Description and InstallationTable 214NT8D41AA DTE/DCE/Fiber switch settingsM

Seite 641

Page 676 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005Figure 159SDI paddle board option switch locations55

Seite 642 - Figure 148

NT8D41AA Serial Data Interface Paddle Board Page 677 of 906Circuit Card Description and InstallationSoftware service changesOnce the NT8D41 SDI padd

Seite 643 - Incoming calls to near end

Page 678 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005ApplicationsThe NT8D41AA Serial Data Interface paddl

Seite 644 - Note:

NT8D41AA Serial Data Interface Paddle Board Page 679 of 906Circuit Card Description and InstallationFigure 160SDI paddle board cablingModulefrontNT8

Seite 645

Page 68 of 906 Overview553-3001-211 Standard 3.00 August 2005Figure 13Network connections to IPE modulesNT8D04SuperloopNetworkCardNT8D01ControllerCar

Seite 646

Page 680 of 906 NT8D41AA Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005

Seite 647 - 553-AAA1153

Page 681 of 906Circuit Card Description and Installation694NT8D41BA Quad Serial Data InterfacePaddle BoardContentsThis section contains information on

Seite 648

Page 682 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005• NT6D39 CPU/Network module• NT9D11 Core/Networ

Seite 649

NT8D41BA Quad Serial Data Interface Paddle Board Page 683 of 906Circuit Card Description and InstallationFigure 161NT8D41BA QSDI paddle board1234ON^

Seite 650

Page 684 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005Other logic on the card includes baud rate gene

Seite 651

NT8D41BA Quad Serial Data Interface Paddle Board Page 685 of 906Circuit Card Description and InstallationThe QSDI paddle board is normally installed

Seite 652

Page 686 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 20058 CTS Clear to send (Note 1) Clear to sendNote

Seite 653

NT8D41BA Quad Serial Data Interface Paddle Board Page 687 of 906Circuit Card Description and InstallationConfiguring the QSDI paddle boardConfigurin

Seite 654

Page 688 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005* For future use.Address Switch SW15 or SW16 an

Seite 655

NT8D41BA Quad Serial Data Interface Paddle Board Page 689 of 906Circuit Card Description and InstallationSW15 and SW16 must not be configured identi

Seite 656

Overview Page 69 of 906Circuit Card Description and Installationlink is composed of two asynchronous serial buses (called the Async card LAN link in

Seite 657 - 553-AAA1155

Page 690 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005DTE/DCE/Fiber modeEach serial port can be confi

Seite 658

NT8D41BA Quad Serial Data Interface Paddle Board Page 691 of 906Circuit Card Description and InstallationSoftware service changesOnce the NT8D841BA

Seite 659 - 553-6200

Page 692 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005ApplicationsThe NT8D41BA Quad Serial Data Inter

Seite 660

NT8D41BA Quad Serial Data Interface Paddle Board Page 693 of 906Circuit Card Description and InstallationFigure 163NT8D41BA QSDI paddle board cablin

Seite 661 - Software service entries

Page 694 of 906 NT8D41BA Quad Serial Data Interface Paddle Board553-3001-211 Standard 3.00 August 2005

Seite 662

Page 695 of 906Circuit Card Description and Installation700NTAG26 XMFR cardContentsThis section contains information on the following topics:Introduct

Seite 663 - Pad orientation

Page 696 of 906 NTAG26 XMFR card553-3001-211 Standard 3.00 August 2005Table 219 lists the frequency values used for received signals.Table 219MF freq

Seite 664

NTAG26 XMFR card Page 697 of 906Circuit Card Description and InstallationXMFR receiver specificationsTable 220 provides the operating requirements f

Seite 665

Page 698 of 906 NTAG26 XMFR card553-3001-211 Standard 3.00 August 2005Noise Rejection:Error Rate in White NoiseBetter than: < 1/2500 callsTest:10

Seite 666 - Figure 156

NTAG26 XMFR card Page 699 of 906Circuit Card Description and InstallationThe XMFR receiver specifications conform to the following:• TR-NPL-000258,

Seite 667 - Paddle Board

Contents Page 7 of 906Circuit Card Description and InstallationQPC414 Network card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 668

Page 70 of 906 Overview553-3001-211 Standard 3.00 August 2005trunk line through an impedance matching and balance network. The trunk interface also i

Seite 669 - NT8D41AA SDI paddle board

Page 700 of 906 NTAG26 XMFR card553-3001-211 Standard 3.00 August 2005Physical specificationsThe physical specifications required by the NTAG26 XMFR

Seite 670

Page 701 of 906Circuit Card Description and Installation708NTAK02 SDI/DCH cardContentsThis section contains information on the following topics:Introd

Seite 671

Page 702 of 906 NTAK02 SDI/DCH card553-3001-211 Standard 3.00 August 2005Ports 1 and 3 are configured as DCH. Ports 0 and 2 are configured as SDI (no

Seite 672

NTAK02 SDI/DCH card Page 703 of 906Circuit Card Description and InstallationTwo ports offer the option for DTE/DCE configuration. This option is sel

Seite 673 - Option switch settings

Page 704 of 906 NTAK02 SDI/DCH card553-3001-211 Standard 3.00 August 2005Connecting to the portsExternal devices are connected to the SDI/DCH card by

Seite 674 - DTE/DCE/Fiber mode

NTAK02 SDI/DCH card Page 705 of 906Circuit Card Description and InstallationTable 226NTAK02 connections at the cross-connect terminal – Port 1RS422

Seite 675

Page 706 of 906 NTAK02 SDI/DCH card553-3001-211 Standard 3.00 August 2005Table 227NTAK02 connections at the cross-connect terminal – Port 2RS422 RS2

Seite 676 - 553-5988

NTAK02 SDI/DCH card Page 707 of 906Circuit Card Description and InstallationTable 228NTAK02 connections at the cross-connect terminal – Port 3RS422

Seite 677 - Software service changes

Page 708 of 906 NTAK02 SDI/DCH card553-3001-211 Standard 3.00 August 2005Characteristics of the low speed portPorts 0 and 2 are asynchronous, low spe

Seite 678

Page 709 of 906Circuit Card Description and Installation720NTAK09 1.5 Mb DTI/PRI cardContentsThis section contains information on the following topics

Seite 679 - Equipment identification

Overview Page 71 of 906Circuit Card Description and InstallationVariable gain filtersAudio signals received from the analog phone trunk are passed t

Seite 680

Page 710 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005Physical descriptionThe DTI/PRI card uses a 9.5" by 12.5" m

Seite 681

NTAK09 1.5 Mb DTI/PRI card Page 711 of 906Circuit Card Description and InstallationThe first five LEDs operate as follows:• During system power up,

Seite 682

Page 712 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005NTAK09 DTI/PRI power on self-testWhen power is applied to the NTAK09

Seite 683 - 553-8009

NTAK09 1.5 Mb DTI/PRI card Page 713 of 906Circuit Card Description and InstallationNTAK93 self-testThe NTAK93 DCHI daughterboard LED is the bottom L

Seite 684 - System considerations

Page 714 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005The NTAK09 circuit card conforms to safety and performance standards

Seite 685

NTAK09 1.5 Mb DTI/PRI card Page 715 of 906Circuit Card Description and InstallationArchitectureSignaling interfaceThe signaling interface performs a

Seite 686

Page 716 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005Digital padThe digital pad is an EPROM whose address-input to data-ou

Seite 687

NTAK09 1.5 Mb DTI/PRI card Page 717 of 906Circuit Card Description and InstallationD-channel interfaceThe D-channel interface is a 64 Kbps maximum,

Seite 688 - (Part 2 of 2)

Page 718 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005extend from the card to the DSX-1 or LD-1. Equalizers are switch sele

Seite 689

NTAK09 1.5 Mb DTI/PRI card Page 719 of 906Circuit Card Description and InstallationClock controller interfaceThe clock controller interface provides

Seite 690

Page 72 of 906 Overview553-3001-211 Standard 3.00 August 2005Serial Data Interface (SDI) cardsThe NT8D41BA QSDI paddle board provides four bidirectio

Seite 691

Page 720 of 906 NTAK09 1.5 Mb DTI/PRI card553-3001-211 Standard 3.00 August 2005

Seite 692

Page 721 of 906Circuit Card Description and Installation734NTAK10 2.0 Mb DTI cardContentsThis section contains information on the following topics:Int

Seite 693

Page 722 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005Physical descriptionThe 2 Mb DTI pack uses a standard 9.5" by 12.5&q

Seite 694

NTAK10 2.0 Mb DTI card Page 723 of 906Circuit Card Description and InstallationPower requirementsThe 2MB DTI obtains its power from the backplane. I

Seite 695 - NTAG26 XMFR card

Page 724 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005• per-channel and all-channel loopback capabilities for near-end and far-

Seite 696

NTAK10 2.0 Mb DTI card Page 725 of 906Circuit Card Description and InstallationTransmit dataTo transmit data on the carrier, the incoming serial bit

Seite 697 - XMFR receiver specifications

Page 726 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005• controlling LEDs• downloading Local Calling Areas (LCAs)• monitoring er

Seite 698

NTAK10 2.0 Mb DTI card Page 727 of 906Circuit Card Description and InstallationIf a coaxial interface is required, use NT5K85 in conjunction with th

Seite 699

Page 728 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005With the exception of the outpulsing signals and special signals, such as

Seite 700

NTAK10 2.0 Mb DTI card Page 729 of 906Circuit Card Description and Installationconverted from digital to AMI and sent to the carrier. A transformer

Seite 701 - NTAK02 SDI/DCH card

Overview Page 73 of 906Circuit Card Description and Installationnot consume a module slot. The RS-232-C connections are brought out through special

Seite 702 - DCH function in the U.K

Page 730 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005Tracking modeThere are two stages to clock controller tracking: • trackin

Seite 703

NTAK10 2.0 Mb DTI card Page 731 of 906Circuit Card Description and InstallationClock controller functions and featuresThe NTAK10 2MB DTI clock contr

Seite 704 - Connecting to the ports

Page 732 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005secondary, but switches over to the primary whenever the primary recovers

Seite 705

NTAK10 2.0 Mb DTI card Page 733 of 906Circuit Card Description and InstallationReference clock interfaceThe recovered clock derived from the facilit

Seite 706

Page 734 of 906 NTAK10 2.0 Mb DTI card553-3001-211 Standard 3.00 August 2005

Seite 707

Page 735 of 906Circuit Card Description and Installation744NTAK20 Clock Controller daughterboardContentsThis section contains information on the follo

Seite 708

Page 736 of 906 NTAK20 Clock Controller daughterboard553-3001-211 Standard 3.00 August 2005Note: The card is restricted to slots 1 through 3 in EMC-

Seite 709 - NTAK09 1.5 Mb DTI/PRI card

NTAK20 Clock Controller daughterboard Page 737 of 906Circuit Card Description and Installation• jitter filtering• use of an algorithm to detect crys

Seite 710

Page 738 of 906 NTAK20 Clock Controller daughterboard553-3001-211 Standard 3.00 August 2005Free-run (non-tracking)In free-run mode, the clock control

Seite 711

NTAK20 Clock Controller daughterboard Page 739 of 906Circuit Card Description and InstallationFunctional descriptionThe main functional blocks of th

Seite 712 - NTAK20 power on self-test

Page 74 of 906 Overview553-3001-211 Standard 3.00 August 2005— Data terminal equipment (DTE) emulation mode— Data communication equipment (DCE) emula

Seite 713 - DTI/PRI local self-test

Page 740 of 906 NTAK20 Clock Controller daughterboard553-3001-211 Standard 3.00 August 2005System clock specification and characteristicsSince the ac

Seite 714

NTAK20 Clock Controller daughterboard Page 741 of 906Circuit Card Description and Installationwithout software intervention. If both references are

Seite 715

Page 742 of 906 NTAK20 Clock Controller daughterboard553-3001-211 Standard 3.00 August 2005Holdover and free-runIn the temporary absence of a synchro

Seite 716 - Digital pad

NTAK20 Clock Controller daughterboard Page 743 of 906Circuit Card Description and Installationbackplane line. It designates the DTI/PRI motherboard

Seite 717 - DS-1 Carrier interface

Page 744 of 906 NTAK20 Clock Controller daughterboard553-3001-211 Standard 3.00 August 2005

Seite 718

Page 745 of 906Circuit Card Description and Installation762NTAK79 2.0 Mb PRI card ContentsThis section contains information on the following topics:In

Seite 719 - Clock rate converter

Page 746 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Note: Clocking slips can occur between MG 1000S systems that are clocked

Seite 720

NTAK79 2.0 Mb PRI card Page 747 of 906Circuit Card Description and InstallationRED On (Red) A red alarm state has been detected. This represents a l

Seite 721 - NTAK10 2.0 Mb DTI card

Page 748 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005NTAK79 switchesThe NTAK79 card incorporates four on-board dip switches. T

Seite 722

NTAK79 2.0 Mb PRI card Page 749 of 906Circuit Card Description and InstallationFigure 165NTAK79 card with switch locations121212 12553-7869.EPSLEDsJ

Seite 723

Overview Page 75 of 906Circuit Card Description and InstallationPower consumptionThe SDI cards obtain their power directly from the module backplane

Seite 724

Page 750 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Switch SW1 – DCHI ConfigurationThis switch enables/disables the on-board

Seite 725

NTAK79 2.0 Mb PRI card Page 751 of 906Circuit Card Description and InstallationSwitch SW4 – Carrier Shield GroundingThis switch enables for the sele

Seite 726

Page 752 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005• monitoring of receive carrier alarms including AIS, LOS, and RAI• trans

Seite 727

NTAK79 2.0 Mb PRI card Page 753 of 906Circuit Card Description and InstallationThe incoming serial bit stream is converted to 8-bit parallel bytes t

Seite 728 - Carrier interface

Page 754 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Signaling interfaceThe signaling interface consists of the A07 DS-30X sig

Seite 729

NTAK79 2.0 Mb PRI card Page 755 of 906Circuit Card Description and InstallationImpedance matchingThe line interface provides for the use of either 7

Seite 730

Page 756 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005requirements of the CCITT recommendation G.742. This provides jitter atte

Seite 731

NTAK79 2.0 Mb PRI card Page 757 of 906Circuit Card Description and Installation• receive clock output • transmit clock output The receive and transm

Seite 732

Page 758 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Card-LAN interfaceA Dual Port UART handles the functions of the serial po

Seite 733 - Switch settings

NTAK79 2.0 Mb PRI card Page 759 of 906Circuit Card Description and InstallationIf the incoming clock reference is stable, the internal clock control

Seite 734

Page 76 of 906 Overview553-3001-211 Standard 3.00 August 2005Electromagnetic interference The CS 1000S, CS 1000M, and Meridian 1 systems meet the req

Seite 735

Page 760 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005• jitter filtering• use of an algorithm to detect crystal aging and to qu

Seite 736

NTAK79 2.0 Mb PRI card Page 761 of 906Circuit Card Description and InstallationA time-out mechanism prevents chatter due to repeated automatic switc

Seite 737 - Clocking modes

Page 762 of 906 NTAK79 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005

Seite 738

Page 763 of 906Circuit Card Description and Installation768NTAK93 D-channel Handler Interface daughterboardContentsThis section contains information o

Seite 739

Page 764 of 906 NTAK93 D-channel Handler Interface daughterboard553-3001-211 Standard 3.00 August 2005— system parameters are service changeable (sys

Seite 740

NTAK93 D-channel Handler Interface daughterboard Page 765 of 906Circuit Card Description and InstallationFaceplate LEDsNTAK09 1.5 Mb PRI and NTBK50

Seite 741 - Digital to analog converter

Page 766 of 906 NTAK93 D-channel Handler Interface daughterboard553-3001-211 Standard 3.00 August 2005DMA controllerA Z80A-DMA chip controls the data

Seite 742 - Microprocessor

NTAK93 D-channel Handler Interface daughterboard Page 767 of 906Circuit Card Description and InstallationThe port will operate at:The address of por

Seite 743 - External timing interface

Page 768 of 906 NTAK93 D-channel Handler Interface daughterboard553-3001-211 Standard 3.00 August 2005

Seite 744

Page 769 of 906Circuit Card Description and Installation772NTBK22 MISP cardContentsThis section contains information on the following topics:Introduct

Seite 745 - NTAK79 2.0 Mb PRI card

Overview Page 77 of 906Circuit Card Description and InstallationThe following maintenance program is used to maintain individual SDI synchronous por

Seite 746

Page 770 of 906 NTBK22 MISP card553-3001-211 Standard 3.00 August 2005Refer to ISDN Basic Rate Interface: Installation and Configuration (553-3001-21

Seite 747

NTBK22 MISP card Page 771 of 906Circuit Card Description and InstallationHigh-Level Data Link Controller (HDLC)The HDLC is a format converter that s

Seite 748 - NTAK79 switches

Page 772 of 906 NTBK22 MISP card553-3001-211 Standard 3.00 August 2005

Seite 749 - Switch 4Switch 2

Page 773 of 906Circuit Card Description and Installation784NTBK50 2.0 Mb PRI card ContentsThis section contains information on the following topics:In

Seite 750

Page 774 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005You can install this card in slots 1 through 4 in the MG 1000S. The card

Seite 751

NTBK50 2.0 Mb PRI card Page 775 of 906Circuit Card Description and InstallationFigure 166NTBK50 2.0 Mb PRI card with daughterboardsNTAK20 ClockContr

Seite 752

Page 776 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005The LEDs are described in Table 249.Table 249NTBK50 faceplate LEDs (Part

Seite 753 - PAD Offset PA D

NTBK50 2.0 Mb PRI card Page 777 of 906Circuit Card Description and InstallationPower requirementsThe NTBK50 obtains its power from the backplane, dr

Seite 754

Page 778 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005• monitoring of receive carrier alarms including AIS, LOS, and RAI• trans

Seite 755 - Carrier grounding

NTBK50 2.0 Mb PRI card Page 779 of 906Circuit Card Description and Installationmessage format; eight are assigned to voice/data (64 Kbps), one to si

Seite 756 - D-channel support interface

Page 78 of 906 Overview553-3001-211 Standard 3.00 August 2005

Seite 757

Page 780 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Signaling interfaceThe signaling interface consists of the A07 DS-30X sig

Seite 758 - Card-LAN interface

NTBK50 2.0 Mb PRI card Page 781 of 906Circuit Card Description and InstallationImpedance matching (Switch SW2)The line interface provides for the us

Seite 759

Page 782 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005Carrier Shield grounding (Switch SW4)Table 253 lists the Carrier Shield g

Seite 760

NTBK50 2.0 Mb PRI card Page 783 of 906Circuit Card Description and InstallationCEPT transceiverThe transmitter and receiver functions are used for s

Seite 761

Page 784 of 906 NTBK50 2.0 Mb PRI card553-3001-211 Standard 3.00 August 2005mode, which is not supported at this time. The DDCH supports only a singl

Seite 762

Page 785 of 906Circuit Card Description and Installation790NTBK51 Downloadable D-channel Handler daughterboardContentsThis section contains informatio

Seite 763 - Interface daughterboard

Page 786 of 906 NTBK51 Downloadable D-channel Handler daughterboard553-3001-211 Standard 3.00 August 2005— DCH interface— layer 3 preprocessor— traff

Seite 764

NTBK51 Downloadable D-channel Handler daughterboard Page 787 of 906Circuit Card Description and InstallationFunctional descriptionThe main functiona

Seite 765

Page 788 of 906 NTBK51 Downloadable D-channel Handler daughterboard553-3001-211 Standard 3.00 August 2005Main memoryThe main 68EC020 system memory is

Seite 766

NTBK51 Downloadable D-channel Handler daughterboard Page 789 of 906Circuit Card Description and InstallationSanity timerA sanity timer is incorporat

Seite 767 - D-Port — SDTI/PRI interface

Page 79 of 906Circuit Card Description and Installation88Circuit card installationContentsThis section contains information on the following topics:Ca

Seite 768

Page 790 of 906 NTBK51 Downloadable D-channel Handler daughterboard553-3001-211 Standard 3.00 August 2005download depends on the result of the check

Seite 769 - NTBK22 MISP card

Page 791 of 906Circuit Card Description and Installation810NTCK16 Generic Central OfficeTrunk cardsContentsThis section contains information on the fo

Seite 770

Page 792 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005The cards are identified by a two-letter suffix to the

Seite 771 - Power consumption

NTCK16 Generic Central Office Trunk cards Page 793 of 906Circuit Card Description and InstallationPhysical descriptionThe NTCK16AX and NTCK16BX gene

Seite 772

Page 794 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005• provide 4 dB dynamic attenuation pads on a per call

Seite 773 - NTBK50 2.0 Mb PRI card

NTCK16 Generic Central Office Trunk cards Page 795 of 906Circuit Card Description and InstallationCall placed by Central OfficeThe Central Office in

Seite 774

Page 796 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Electrical specificationsPower requirementsTable 256 s

Seite 775 - 553-CSE7872

NTCK16 Generic Central Office Trunk cards Page 797 of 906Circuit Card Description and InstallationPad switchingThe NTCK16AX and NTCK16BX generic Cen

Seite 776

Page 798 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Figure 167NTCK16 Central Office trunk connections for

Seite 777

NTCK16 Generic Central Office Trunk cards Page 799 of 906Circuit Card Description and InstallationFigure 168NTCK16 Central Office trunk connections

Seite 778

Page 8 of 906 Contents 553-3001-211 Standard 3.00 August 2005Front panel connector pin assignments .. . . . . . . . . . . . . . . . . . . . . . . . 1

Seite 779

Page 80 of 906 Circuit card installation553-3001-211 Standard 3.00 August 2005Circuit card installationTable 12Large System card slots (Part 1 of 4)C

Seite 780

Page 800 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Figure 169NTCK16 Central Office trunk connections for

Seite 781

NTCK16 Generic Central Office Trunk cards Page 801 of 906Circuit Card Description and InstallationNTCK16AX Central Office trunk cardRoute Data Block

Seite 782

Page 802 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Trunk Data BlockRespond to the prompts in LD 14 as sho

Seite 783

NTCK16 Generic Central Office Trunk cards Page 803 of 906Circuit Card Description and InstallationNote: These prompts are required only for the firs

Seite 784

Page 804 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005NTCK16BX Central Office trunk cardRoute Data BlockResp

Seite 785 - Handler daughterboard

NTCK16 Generic Central Office Trunk cards Page 805 of 906Circuit Card Description and InstallationTrunk Data BlockRespond to the prompts in LD 14 as

Seite 786

Page 806 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Note 1: These prompts are required only for the first

Seite 787

NTCK16 Generic Central Office Trunk cards Page 807 of 906Circuit Card Description and InstallationBTID values by countryCountryBTIDCadenceBrazil Tor

Seite 788

Page 808 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005Detection limits Pulses detected by the NTCK16AX circu

Seite 789 - Download operation

NTCK16 Generic Central Office Trunk cards Page 809 of 906Circuit Card Description and InstallationTherefore the following steps must be followed whe

Seite 790 - Background audit

Circuit card installation Page 81 of 906Circuit Card Description and InstallationNT5K02 Analog Line card IPE: any slot but “Contr”NT5K07 Universal

Seite 791

Page 810 of 906 NTCK16 Generic Central Office Trunk cards553-3001-211 Standard 3.00 August 2005EquivalenciesThe following equivalencies do apply:• XF

Seite 792

Page 811 of 906Circuit Card Description and Installation824NTDK20 Small System Controller cardContentsThis section contains information on the followi

Seite 793

Page 812 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005The NTDK20GA SSC card has the following components and featu

Seite 794

NTDK20 Small System Controller card Page 813 of 906Circuit Card Description and InstallationFigure 170NTDK20 SSC card and expansion daughterboard in

Seite 795

Page 814 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005MemoryThe majority of system and customer configured data is

Seite 796

NTDK20 Small System Controller card Page 815 of 906Circuit Card Description and Installation100BaseT IP daughterboards A 100BaseT IP Daughterboard m

Seite 797

Page 816 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005Figure 171NTDK83AA dual-port 100BaseT IP daughterboard Figur

Seite 798 - Figure 167

NTDK20 Small System Controller card Page 817 of 906Circuit Card Description and InstallationNote: If not connecting point-to-point, connect the Call

Seite 799 - Figure 168

Page 818 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005Figure 173Call Server connection to Media Gateway 1000S syst

Seite 800 - Figure 169

NTDK20 Small System Controller card Page 819 of 906Circuit Card Description and InstallationSecurity deviceThe NTDK20 SSC card in each MG 1000S must

Seite 801 - Route Data Block

Page 82 of 906 Circuit card installation553-3001-211 Standard 3.00 August 2005NT6D71U Interface Line cardIPE: any slot but “Contr”NT6D72Basic Rate Si

Seite 802 - Trunk Data Block

Page 820 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005SDI portsThe NTDK20 SSC card in both the Call Server and the

Seite 803

NTDK20 Small System Controller card Page 821 of 906Circuit Card Description and InstallationThe MG 1000S 10BaseT port can run in Normal mode or Surv

Seite 804

Page 822 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005Table 261MG 1000S and MG 1000S Expansion slot assignmentsMG

Seite 805

NTDK20 Small System Controller card Page 823 of 906Circuit Card Description and InstallationFigure 174MG 1000S slotsMedia Gateway 1000553-AAA1991

Seite 806 - Prompt Response Description

Page 824 of 906 NTDK20 Small System Controller card553-3001-211 Standard 3.00 August 2005Figure 175MG 1000S Expansion slots 553-AAA1992Media Gateway

Seite 807

Page 825 of 906Circuit Card Description and Installation838NTRB21 DTI/PRI/DCH TMDI cardContentsThis section contains information on the following topi

Seite 808 - Loss switching

Page 826 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005To provide CEMUX communication with the card, changes are also requ

Seite 809

NTRB21 DTI/PRI/DCH TMDI card Page 827 of 906Circuit Card Description and InstallationFigure 176NTRB21 TMDI card with clock controllerOOSACTREDYELLBK

Seite 810 - Call disconnect

Page 828 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005In general, the first five LEDs operate as follows:• During system

Seite 811 - Controller card

NTRB21 DTI/PRI/DCH TMDI card Page 829 of 906Circuit Card Description and InstallationFigure 177NTRB21 TMDI card faceplate55 3-CSE0 007OOSACTREDYELLB

Seite 812

Circuit card installation Page 83 of 906Circuit Card Description and InstallationNTCK43AA Primary Rate Interface card Core/Net: 0-7Net: 5-11, 13-14N

Seite 813 - Figure 170

Page 830 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005Foreign and surge voltage protectionLightning protectors must be in

Seite 814 - NTTK25 daughterboard

NTRB21 DTI/PRI/DCH TMDI card Page 831 of 906Circuit Card Description and InstallationSoftware descriptionChanges from the NTAK09 are required for th

Seite 815 - 100BaseT IP daughterboards

Page 832 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005Figure 178NTRB21 TMDI card faceplateTMDIRxTxOOSACTREDYELLBKCCDCH...

Seite 816

NTRB21 DTI/PRI/DCH TMDI card Page 833 of 906Circuit Card Description and InstallationMicroprocessorThe NTRB21 is equipped with bit-slice microproces

Seite 817

Page 834 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005D-channel interfaceThe D-channel interface is a 64 kbps, full-duple

Seite 818 - PC card interface

NTRB21 DTI/PRI/DCH TMDI card Page 835 of 906Circuit Card Description and Installation• receive clock output • transmit clock output The bit rate of

Seite 819 - Security device

Page 836 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005Cross-connect – Level 1 (DSX-1), or LD-1. Equalizers are switch sel

Seite 820 - Conferencing

NTRB21 DTI/PRI/DCH TMDI card Page 837 of 906Circuit Card Description and InstallationConnector pinoutThe connection to the external digital carrier

Seite 821

Page 838 of 906 NTRB21 DTI/PRI/DCH TMDI card553-3001-211 Standard 3.00 August 2005Note: Clocking slips can occur between MG 1000S systems that are cl

Seite 822 - * Not supported

Page 839 of 906Circuit Card Description and Installation844NTVQ01xx Media CardContentsThis section contains information on the following topics:Physic

Seite 823 - Media Gateway 1000

Page 84 of 906 Circuit card installation553-3001-211 Standard 3.00 August 2005PrecautionsTo avoid personal injury and equipment damage, review the fo

Seite 824 - MG 1000S Expansion slots

Page 840 of 906 NTVQ01xx Media Card553-3001-211 Standard 3.00 August 2005Figure 179NTVQ01xx Media Card The NTVQ01xx Media Card provides faceplate and

Seite 825 - NTRB21 DTI/PRI/DCH TMDI card

NTVQ01xx Media Card Page 841 of 906Circuit Card Description and InstallationHardware architectureThe Media Card comes in two versions: 8-port and 32

Seite 826

Page 842 of 906 NTVQ01xx Media Card553-3001-211 Standard 3.00 August 2005Figure 180NTVQ01xx Media Card faceplateHEX DisplayMaintenance PortEthernet A

Seite 827 - Figure 176

NTVQ01xx Media Card Page 843 of 906Circuit Card Description and InstallationRS-232 Asynchronous Maintenance PortAn 8-pin mini-DIN socket on the NTVQ

Seite 828

Page 844 of 906 NTVQ01xx Media Card553-3001-211 Standard 3.00 August 2005

Seite 829 - NTRB21 TMDI card faceplate

Page 845 of 906Circuit Card Description and Installation850NTVQ55AA ITG Pentium cardContentsThis section contains information on the following topics:

Seite 830

Page 846 of 906 NTVQ55AA ITG Pentium card553-3001-211 Standard 3.00 August 2005Functional descriptionFigure 181 on page 847 shows the ITG-P card face

Seite 831 - Hardware description

NTVQ55AA ITG Pentium card Page 847 of 906Circuit Card Description and InstallationFigure 181NTVQ55AA ITG-P card faceplate Note: There are no Etherne

Seite 832

Page 848 of 906 NTVQ55AA ITG Pentium card553-3001-211 Standard 3.00 August 2005NWK Status LEDNWK Status LEDs display the TLAN interface card Ethernet

Seite 833

NTVQ55AA ITG Pentium card Page 849 of 906Circuit Card Description and Installation• alternate connection to the serial maintenance port DS-30X • Car

Seite 834

Circuit card installation Page 85 of 906Circuit Card Description and Installation• Keep cards installed in the system as much as possible to avoid d

Seite 835

Page 850 of 906 NTVQ55AA ITG Pentium card553-3001-211 Standard 3.00 August 2005

Seite 836

Page 851 of 906Circuit Card Description and Installation868QPC513 Enhanced Serial Data Interface cardContentsThis section contains information on the

Seite 837

Page 852 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Each system can accommodate up to eight ESDI cards, f

Seite 838

QPC513 Enhanced Serial Data Interface card Page 853 of 906Circuit Card Description and InstallationFigure 182CPC513 ESDI card front panelLEDCardlock

Seite 839 - NTVQ01xx Media Card

Page 854 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Functional descriptionThe QPC513 ESDI card is an inte

Seite 840 - Figure 179

QPC513 Enhanced Serial Data Interface card Page 855 of 906Circuit Card Description and InstallationThe QPC513 ESDI card is an intelligent controller

Seite 841 - Hardware architecture

Page 856 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Clock timing optionThe ESDI card offers two timing op

Seite 842 - 553-MIRAN0001

QPC513 Enhanced Serial Data Interface card Page 857 of 906Circuit Card Description and InstallationFault detectionFirmware on the ESDI card detects

Seite 843 - Survivability

Page 858 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Electrical interface optionsInterface options are sel

Seite 844

QPC513 Enhanced Serial Data Interface card Page 859 of 906Circuit Card Description and InstallationConnector pin assignmentsTable 268 shows the pin

Seite 845 - NTVQ55AA ITG Pentium card

Page 86 of 906 Circuit card installation553-3001-211 Standard 3.00 August 2005• Hardware disable cards, whenever there is an enable/disable switch, b

Seite 846

Page 860 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 200517 Receiver signal element timing (DCE) — 3 DD24 Tran

Seite 847 - 553-CSE9150

QPC513 Enhanced Serial Data Interface card Page 861 of 906Circuit Card Description and InstallationTiming12Transmitter signal element tim-ing (DTE)

Seite 848 - Backplane interfaces

Page 862 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Configuring the ESDI cardConfiguring the ESDI card co

Seite 849 - Assembly description

QPC513 Enhanced Serial Data Interface card Page 863 of 906Circuit Card Description and InstallationDTE/DCE mode jumper settingsThe interface for eac

Seite 850

Page 864 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Figure 185ESDI card option switch locations553-5983S1

Seite 851 - Interface card

QPC513 Enhanced Serial Data Interface card Page 865 of 906Circuit Card Description and InstallationSoftware service changesAll of the other ESDI por

Seite 852

Page 866 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005parameters. These parameters must be set for each por

Seite 853 - CPC513 ESDI card front panel

QPC513 Enhanced Serial Data Interface card Page 867 of 906Circuit Card Description and InstallationApplicationsThe QPC513 Enhanced Serial Data Inter

Seite 854

Page 868 of 906 QPC513 Enhanced Serial Data Interface card553-3001-211 Standard 3.00 August 2005Figure 186QPC513 ESDI card cablingCables to periphera

Seite 855 - Synchronous communication

Page 869 of 906Circuit Card Description and Installation884QPC841 Quad Serial Data Interface cardContentsThis section contains information on the foll

Seite 856 - Test and maintenance features

Circuit card installation Page 87 of 906Circuit Card Description and Installation7 Insert the card into the card aligning guides in the card cage. G

Seite 857 - Connection characteristics

Page 870 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005QSDI cards are housed in the following modules:• NT5D21 C

Seite 858 - Figure 184

QPC841 Quad Serial Data Interface card Page 871 of 906Circuit Card Description and InstallationFigure 187QPC841 QSDI card front panelLEDCardlock lat

Seite 859

Page 872 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005Functional descriptionThe QPC841 Quad Serial Data Interfa

Seite 860

QPC841 Quad Serial Data Interface card Page 873 of 906Circuit Card Description and InstallationFigure 188QPC841 QSDI card block diagramUARTno. 1UART

Seite 861

Page 874 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005Connector pin assignmentsConnector J1 is connected to por

Seite 862 - Configuring the ESDI card

QPC841 Quad Serial Data Interface card Page 875 of 906Circuit Card Description and InstallationTable 274Connector J2 pin assignments (Part 1 of 2)Pi

Seite 863 - DTE/DCE mode jumper settings

Page 876 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005Configuring the QSDI cardConfiguring the QSDI card consis

Seite 864 - 553-5983

QPC841 Quad Serial Data Interface card Page 877 of 906Circuit Card Description and Installationselect the addresses for ports 1 and 2. Switch SW15 i

Seite 865

Page 878 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005Baud rate switch settingsTable 276 lists the switch setti

Seite 866

QPC841 Quad Serial Data Interface card Page 879 of 906Circuit Card Description and InstallationDTE/DCE mode switch settingsTable 277 shows the DTE/D

Seite 867

Page 88 of 906 Circuit card installation553-3001-211 Standard 3.00 August 20059 If there is an enable/disable switch, set it to Enb.Note: Do not enab

Seite 868

Page 880 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005Figure 189QSDI card option switch locations553-5987SW1DS1

Seite 869

QPC841 Quad Serial Data Interface card Page 881 of 906Circuit Card Description and InstallationSoftware service changesOnce the QPC841 QSDI card has

Seite 870

Page 882 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005ApplicationsThe QPD841 Quad Serial Data Interface (QSDI)

Seite 871 - QPC841 QSDI card front panel

QPC841 Quad Serial Data Interface card Page 883 of 906Circuit Card Description and Installation• SDI multiple-port cable (internal system options us

Seite 872

Page 884 of 906 QPC841 Quad Serial Data Interface card553-3001-211 Standard 3.00 August 2005

Seite 873 - Figure 188

Page 885 of 906Circuit Card Description and Installation900The TDS/DTR cardContentsThis section contains information on the following topics:Introduct

Seite 874

Page 886 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005FeaturesTone transmitter The TDS/DTR tone transmitter provides 30 channels of t

Seite 875

The TDS/DTR card Page 887 of 906Circuit Card Description and InstallationTones and cadencesThe following tables give the tones and cadences provided

Seite 876 - Configuring the QSDI card

Page 888 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 200519 770/1340 -12/-10 520 770/1480 -12/-10 621 850/1210 -12/-10 722 850/1340 -12/

Seite 877

The TDS/DTR card Page 889 of 906Circuit Card Description and Installation39 770/1210 -17/-15 440 770/1340 -17/-15 541 770/1480 -17/-15 642 850/1210

Seite 878 - Baud rate switch settings

Page 89 of 906Circuit Card Description and Installation100Acceptance testsContentsThis section contains information on the following topics:Introducti

Seite 879

Page 890 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 200560 700/1500 -13/-13 761 900/1500 -13/-13 862 1100/1500 -13/-13 963 700/1700 -13

Seite 880 - Figure 189

The TDS/DTR card Page 891 of 906Circuit Card Description and Installation80 480 -19 ÷81 420 -9 ÷82 440 -29 ÷83 reserved84 350/440 -17/-17 ÷85 400/45

Seite 881

Page 892 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005Note: Tones #1 - 16 (inclusive) and #234 - 249 (inclusive) are included for Nor

Seite 882

The TDS/DTR card Page 893 of 906Circuit Card Description and Installation12 940 X 1210 -14/-13 *13 940 X 1480 -14/-13 #14 700 X 1630 -14/-13 F015 77

Seite 883 - QPC841 QSDI card cabling

Page 894 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005104 850/1630 -13/-12 I105 350/440 -17/-17 ÷106 400/450 -17/-17 ÷107 1400 -26 ÷1

Seite 884

The TDS/DTR card Page 895 of 906Circuit Card Description and Installation125 940/1480 -12/-10 #126 700/1630 -12/-10 F0127 770/1630 -12/-10 F128 850/

Seite 885 - The TDS/DTR card

Page 896 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005146 850/1340 -18/-17 ÷ 8147 850/1480 -18/-17 ÷ 9148 940/1340 -18/-17 ÷ 0149 940

Seite 886

The TDS/DTR card Page 897 of 906Circuit Card Description and Installation167 1700 -19 ÷168 440 -14 ÷169 380 -8 ÷170 1400 -32 ÷171 820 -7 P172 850 -8

Seite 887 - Tones and cadences

Page 898 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005188 420 X 25 -17189 950 -16190 950 -25191 940/1630 -9/-7192 700/1210 -9/-7193 7

Seite 888

The TDS/DTR card Page 899 of 906Circuit Card Description and Installation209 420 -4210 1400 -18211 1400 -9212 350/420 -9/-9213 420 -14214 450 -12215

Seite 889

Contents Page 9 of 906Circuit Card Description and InstallationNT5D97 Dual-port DTI2/PRI2 card . . . . . . . . . . . . . 319Contents .. . . . . . .

Seite 890

Page 90 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005Conference cardsProcedure 2Testing conference cardsUse this procedure to test a

Seite 891

Page 900 of 906 The TDS/DTR card553-3001-211 Standard 3.00 August 2005230 940/1480 -14/-12231 700/1630 -14/-12232 770/1630 -14/-12233 850/1630 -14/-1

Seite 892

Page 901 of 906Circuit Card Description and Installation906Appendix A: LAPB Data Link ControlprotocolContentsThis section contains information on the

Seite 893

Page 902 of 906 Appendix A: LAPB Data Link Control protocol553-3001-211 Standard 3.00 August 2005LAPB subset of the HDLC protocol and transmitted seri

Seite 894

Appendix A: LAPB Data Link Control protocol Page 903 of 906Circuit Card Description and InstallationLAPB balanced class of procedureApplications whic

Seite 895

Page 904 of 906 Appendix A: LAPB Data Link Control protocol553-3001-211 Standard 3.00 August 2005Asynchronous Balanced Mode Asynchronous Balanced Mode

Seite 896

Appendix A: LAPB Data Link Control protocol Page 905 of 906Circuit Card Description and InstallationDescription of procedureThe basic LAPB procedures

Seite 897

Page 906 of 906 Appendix A: LAPB Data Link Control protocol553-3001-211 Standard 3.00 August 2005

Seite 899

Family Product Manual Contacts Copyright FCC notice Trademarks Document number Product release Document release Date PublishNortel Communication Serve

Seite 900

Acceptance tests Page 91 of 906Circuit Card Description and Installation4 Test the conference loop for channel, group, and switching faults:CNFC loo

Seite 901

Page 92 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005Again, see “LD 38” in the Software Input/Output: Maintenance (553-3001-511) for

Seite 902 - Frame structure

Acceptance tests Page 93 of 906Circuit Card Description and InstallationLine cardsProcedure 4Testing line cardsUse this procedure to test a line car

Seite 903

Page 94 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005Multifrequency sender cardsProcedure 5Testing multifrequency sender cardsUse thi

Seite 904 - Commands and responses

Acceptance tests Page 95 of 906Circuit Card Description and InstallationMultifrequency signaling cardsProcedure 6Testing multifrequency signaling ca

Seite 905 - Description of procedure

Page 96 of 906 Acceptance tests553-3001-211 Standard 3.00 August 20053 End the session in LD 30:****End of ProcedureTrunk cardsUse the following proc

Seite 906

Acceptance tests Page 97 of 906Circuit Card Description and InstallationWhen you see the DN? prompt, enter the directory number (DN) you want the sy

Seite 907

Page 98 of 906 Acceptance tests553-3001-211 Standard 3.00 August 2005For other than an NT8D17 Conference/TDS card, enter:ENLL loop4 Test the TDS loop

Seite 908

Acceptance tests Page 99 of 906Circuit Card Description and InstallationRNG#loop## 764#loop## Provides ring tone from TDS loop specified.**** Exits