288 Chapter 23 Replacing or upgrading a power supply
N0060612N0060612
To remove the PSU status connector jumper
1 Shut down the system (see “Performing a system shutdown” on page 231).
2 Disconnect the BCM400 system from the AC power outlet.
3 Remove the main unit top cover. Refer to “Removing the main unit top cover” on page 244.
4 Locate the PSU status connector on the I/O card (see Figure 148).
5 Remove the RPS output signaling connector jumper. Use needle-nose pliers to pull the jumper
out and away from the connector. Place the jumper in a safe location.
6 Connect the PA cable to the PSU status connector (see Figure 148 on page 288).
Figure 148 Remove the PSU status connector jumper
Installing a redundant power supply cage (BCM400 only)
This procedure describes how to install a redundant power supply cage in the BCM400 main unit.
After you install the redundant power supply cage in the main unit, install the two power supply
modules (see “Installing a power supply module” on page 295).
Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.
Note: When you upgrade to a redundant power supply, you must also install a redundant
fan. Refer to “Installing a BCM400 cooling fan” on page 326.