78 Chapter 3 Viewing the BCM system LEDs
N0060612N0060612
Status Indicates the system status.
Six non-blinking LEDs in the center indicate
monitoring software is not active.
Green ON – all monitored services are functioning
Green FLASH – failure in one or more telephony
services
Green OFF – not all services are working
MSC PCI Device/MSC Green ON – device is present and operating
properly
Green FLASH – driver is not running
Green OFF – device is defective or not present
WAN PCI Device/WAN1 + WAN2 Green ON – device is present and operating
properly
Green FLASH – driver is not running
Green OFF – device is defective or not present
Modem PCI Device/Modem Green ON – device is present and operating
properly
Green FLASH – driver is not running
Green OFF – device is defective or not present
LAN 1 PCI Device/LAN 1 Green ON – device is present and operating
properly
Green FLASH – driver is not running
Green OFF – device is defective or not present
LAN 2 PCI Device/LAN 2 Green ON – device is present and operating
properly
Green FLASH – driver is not running
Green OFF – device is defective or not present
Table 18 Base function tray system status LED states (Sheet 2 of 3)
LED Description LED states