Common Tops log messages (0202) DNC Logs 27
TOPS VSN Log and alarm messages
Description:
The PRU encountered an error during an IO operation on the
file or directory. The operation was not performed. It is the responsibility of the
PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
Close all files that do not need to be open. If the PRU is in the
working state, no action is required. If the PRU is in the faulty state, then reboot
the PRU. If the problem persists, then reboot the server which handles the IO
operation. If neither reboot operations are successful, then reboot the whole
system. Document the problem, record all action taken, and then contact NT.
0003/0072
Message:
[PRU_name] received an IO error (Parity_Error) on path
[file/directory_path name]. The "server" error was the result of a parity error in
reading data from the server.
Description:
The PRU encountered an error during an IO operation on the
file or directory. The operation was not performed. It is the responsibility of the
PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU and the file server. If the problem
persists, replace the file server SRU and if necessary, the disk. Document the
problem, record all action taken, and then contact NT.
0003/0073
Message:
[PRU_name] received an IO error (Disk_Write_Protected) on path
[file/directory_path name]. The "server" error was the result of trying to write to
a disk that is write protected. Access SAS utilities and unprotect the server. If it
is the prime disk, use FSPATCH.
Description:
The PRU encountered an error during an IO (write) operation
on the file or directory. The operation was not performed. It is the responsibility
of the PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
Reset the write protect flag of the file server. If the PRU is in the
working state, no further action is required. If the PRU is in the faulty state, then
reboot the PRU and the file server. If the problem persists, replace the file
server SRU and if necessary, the disk. Document the problem, record all action
taken, and then contact NT.
0003/0074
Message:
[PRU_name] received an IO error (No_Directory) on path
[file/directory_path name]. The "server" error was the result of performing an
operation on a directory that does not exit.
Description:
The PRU encountered an error during an IO operation trying to
access a directory. The operation was not performed. It is the responsibility of
the PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If neither reboot operations are
successful, then reboot the whole system. Document the problem, record all
action taken, and then contact NT.