Nortel Networks VSN04 Bedienungsanleitung Seite 52

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 90
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 51
46 Common TOPS VSN log messages (020A)
TOPS VSN Log and alarm messages
0001/0031
Message:
[PRU_NAME] could not interpret a triple read from the SDM.
Table name = [table_name]
Tuple ID = [tuple_name]
"Diagnostic String1"
"Diagnostic String2"
Description:
This log indicates an error in interpreting a field within the
specified tuple.
Action: Re-edit the tuple and verify that the fields are all of the correct type.
0001/0032
Message:
[PRU_NAME] was attempting to perform an SDM "notification
Registration" and failed.
Table name = <table_name>
"Diagnostic String1"
"Diagnostic String2"
Description:
This log indicates the SDM Notification server may be down or
faulty.
Action:
Ensure that the SDM Notification Server is in a working state. If the
problem persists, retain all of the information regarding the problem and contact
your NT representative.
Seitenansicht 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 89 90

Kommentare zu diesen Handbüchern

Keine Kommentare