MCS 4-server Sun Fire V100 Solaris Installation and Commissioning Guide
165
Copyright © 2006 Nortel Networks
Note: If you need to install a redundant gatekeeper, also fill in
the Transport Management and Server Properties tabs and
then blank out the signaling addresses and transport config
fields shown in Table 42, H225 Signaling Address tab,
Ta bl e 4 3, H245 Signaling Address tab, and Ta bl e 4 4 , H.323
Gatekeeper tab. For complete information about the Transport
Management and Server Properties tabs, see the MCS 5100
H.323 Gatekeeper Basics (NN10280-111) document.
2 You will need to create one zone in the H323 Zone Configuration
tab, one domain in the H323 Domain Names tab, and one
endpoint in the H323 EndPoint Configuration tab, as shown in
Ta bl e 4 7, H.323 Zone Configuration tab through Table 49, H.323
Endpoint Configuration tab.
Maximum Number of
Redirections
5 default
Initial Maximum Hop
Value
20 default
Table 46 SIP TCF Base tab (Sheet 2 of 2)
Parameter Recommended value Notes Example
Table 47 H.323 Zone Configuration tab
Parameter Recommended value Notes Example
H323 Zone Name 1-64 characters
H323 Zone
BandWidth
128000 to 38400000
bytes
Table 48 H323 Domain Names tab
Parameter
Recommended
value Notes Example
Fully Qualified
Domain Name
1-100 characters Domain
names must
be unique.