MCS 4-server Sun Fire V100 Solaris Installation and Commissioning Guide
Copyright © 2006 Nortel Networks
Appendix C Verifying the installations
Verifying the database installation
The following commands are executed on the database Sun Fire V100
server using PuTTY SSH into the machine logical IP address.
Example: Open a PuTTY SSH session to 192.168.14.21, Port 22.
Procedure 51 Verifying the database server
At the management pc,
1 Log into the server as nortel/<new nortel user password>
2 After the MCS Base Platform System Software install, execute
the following command to verify IP addressing.
@mcsmcsdb]/export/home/nortel:=> ifconfig -a
lo0:
flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4>
mtu 8232 index 1 inet 127.0.0.1 netmask ff000000
dmfe0:
flags=9040843<UP,BROADCAST,RUNNING,MULTICAST,DEP
RECATED,IPv4,NOFAILOVER> mtu 1500 index 2 inet
192.168.14.22 netmask ffffff00 broadcast 192.168.14.255
groupname imspub
dmfe0:1:
flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4
> mtu 1500 index 2 inet 192.168.14.21 netmask ffffff00
broadcast 192.168.14.255
dmfe1:
flags=69040843<UP,BROADCAST,RUNNING,MULTICAST,DE
PRECATED,IPv4,NOFAILOVER,STANDBY,INACTIVE> mtu
1500 index 3 inet 192.168.14.23 netmask ffffff00 broadcast
192.168.14.255 groupname imspub
3 Look for the entry that starts ‘dmfe0.’ The parameters that follow
show the IP address, subnet mask, and whether the interface is
‘UP.’ This example output shows that dmfe0 is assigned to IP
Seitenansicht 174