198 Installing optional circuit cards
Table 24
Switch settings (Ports 2 and 3)
Port
2
Port
3
SW
1-3
SW
1-4
SDI DCH OFF OFF
SDI DPNSS OFF ON
—
ESDI ON ON
Table 25
Jumper settings
Port
Jumper
location
Stra
p for
DTE
Stra
p for
DCE
Jumper
location RS422 RS232
Port
0
J10 C - B B - A
Port
1
J7
J6
C-B
C-B
B-A
B-A
J9J8 C - B
C-B
B-A
B-A
Port
2
J5 C - B B - A
Port
3
J4
J3
C-B
C-B
B-A
B-A
J2J1 C - B
C-B
B-A
B-A
2
Insert the card in its assigned slot.
You can install the NTAK02 SDI/DCH card in:
•
slots 1 through 10 of the cabinet
•
slots 1 to 3 of the chassis
3
Connect an NTAK19FB four port cable (or an NE-A25B cable) from
the corresponding connector at the back of the chassis. If you use an
NE-A25B cable, terminate this cable at the cross-connect terminal.
Because the NTAK19FB cable is equipped with connectors, it does
not require termination at the cross-connect terminal.
—End—
NT8D14 Universal Trunk card
The Universal Trunk card provides eight analog trunks which can function
in the modes shown in Table 26 "NT8D14 Universal Trunk: modes and
option settings" (page 199).
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310 01.04 Standard
Release 5.0 13 May 2008
Copyright © 2008, Nortel Networks
.