94 Installing the Chassis system
For a system with IP expansion, refer to "Installing IP expansion"
(page 179).
b. Install the NTDK16 48-port Digital Line Card in slot 4 of the chassis.
See Procedure 36 "Installing the NTDK16 48-port Digital Line Card"
(page 210).
The NTDK16 Digital Line Card is not required for the Small System
to operate.
13. Install the optional circuit cards that you wish to have in your Small
System. Refer to "Installing optional circuit cards" (page 193) and ISDN
Basic Rate Interface Maintenance (NN43001-718). Also, refer to your
card slot assignment plan.
14. Install the cross-connect terminal. See "Installing and connecting
cross-connect terminals" (page 213).
Refer to the following procedures:
Procedure 38 "Installing the BIX cross-connect terminal" (page 215)
Procedure 39 "Installing the Krone Test Jack Frame (UK)" (page
219)
15. Install the cables from the chassis to the cross-connect terminal. See
"Installing and connecting cross-connect terminals" (page 213). Refer
to Procedure 41 "Connecting the cables for the Chassis system" (page
225).
16. Install the PFTUs, if provided. See "Installing Power Failure Transfer
Units" (page 229). Refer to Procedure 42 "Installing the PFTU" (page
230).
17. Connect the SDI port cable at the back of the chassis. See "Installing
and connecting SDI and Ethernet network interfaces" (page 237). Refer
to Procedure 43 "Connecting SDI ports on the SSC card" (page 242).
18. If Ether net is required, insert an industry-standard Media Access Unit
(MAU) directly into the Ethernet connector at the back of the chassis.
The Chassis system does not include the MAU. Insert the Ethernet
cable into this MAU. See "Installing and connecting SDI and Ethernet
network interfaces" (page 237). Refer to Procedure 47 "Connecting the
Ethernet cable to the Chassis system" (page 256).
19. Make sure that the DIP switch settings on the power supply are set to
the correct values for ringing voltage, ringing frequency, and message
waiting voltage. See Table 6 "Power supply DIP switch settings" (page
44) through Table 9 "North Amer ican power supply DIP switch settings"
(page 45) for the DIP switch settings.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310 01.04 Standard
Release 5.0 13 May 2008